考虑三次谐波调制的柔直系统交流侧单相接地保护研究Research on single-phase grounding fault protection on the AC side of VSC-HVDC systems considering third harmonic modulation
徐鑫森,徐习东,陈金玉,晁武杰,盛诗意
XU Xinsen,XU Xidong,CHEN Jinyu,CHAO Wujie,SHENG Shiyi
摘要(Abstract):
为了简单可靠地实现柔直系统阀交流侧单相接地保护,针对阀交流侧中性点经阻抗接地的柔直系统,分析了交流侧的零序基波分量与直流侧的共模分量,推导了金属性接地故障下故障端与非故障端的零序基波电压、电流解析式。针对采用三次谐波注入调制策略的柔直系统,分析了三次谐波调制引起的纵向三次谐波电压相位特征,推导了三次谐波电压、电流的表达式,提出了利用中性点零序基波电压和三次谐波电压来判断接地故障及其位置的保护判据,并给出了相应的整定计算方法。不同工况下的仿真结果表明,当保护安装端发生接地故障时保护可以正确动作,当其他端发生接地故障时保护不会误动作。
To achieve simple and reliable single-phase grounding fault protection on the AC side of VSC-HVDC systems, this paper focuses on systems where the neutral point of the converter valve′s AC side is impedance-grounded.The zero-sequence fundamental component on the AC side and the common-mode component on the DC side are analyzed, and analytical expressions for the zero-sequence fundamental voltage and current at both the faulted and non-faulted terminals during a metallic grounding fault are derived. For VSC-HVDC systems utilizing third harmonic injection modulation, the phase characteristics of the longitudinal third harmonic voltage induced by this modulation are examined, and expressions for the third harmonic voltage and current are derived. Based on this analysis, protection criteria using the zero-sequence fundamental voltage and third harmonic voltage at neutral point are proposed to detect grounding faults and determine their location, along with the corresponding setting calculation method.Simulation results under various operating conditions show that the protection mechanism correctly activates when a grounding fault occurs at the protection installation terminal and does not operate erroneously when faults occur at other terminals.
关键词(KeyWords):
柔性直流;模块化多电平换流器;接地故障;继电保护;三次谐波调制
VSC-HVDC;MMC;grounding fault;relay protection;third harmonic modulation
基金项目(Foundation): 国家电网有限公司科技项目(5500-202221124A-1-1-ZN)
作者(Author):
徐鑫森,徐习东,陈金玉,晁武杰,盛诗意
XU Xinsen,XU Xidong,CHEN Jinyu,CHAO Wujie,SHENG Shiyi
DOI: 10.19585/j.zjdl.202410012
参考文献(References):
- [1] FREYTES J,AKKARI S,RAULT P,et al. Dynamic analysis of MMC-based MTDC grids:use of MMC energy to improve voltage behavior[J]. IEEE Transactions on Power Delivery,2019,34(1):137-148.
- [2] TANG G,XU Z,ZHOU Y Z. Impacts of three MMCHVDC configurations on AC system stability under DC line faults[J]. IEEE Transactions on Power Systems,2014,29(6):3030-3040.
- [3] BELHAOUANE M M,AYARI M,GUILLAUD X,et al. Robust control design of MMC-HVDC systems using multivariable optimal guaranteed cost approach[J]. IEEE Transactions on Industry Applications,2019,55(3):2952-2963.
- [4] PIRHADI A,TAVAKOLI BINA M.Design of DC-side fault current limiter for MMC-HVDC systems:safety of the MMC along with frequency stability[J].IET Generation,Transmission&Distribution,2020,14(13):2419-2429.
- [5]李慧,张鹏,刘思嘉.MMC环流抑制策略的暂态分析[J].电力系统保护与控制,2021,49(2):30-38.LI Hui,ZHANG Peng,LIU Sijia. Transient analysis of MMC circulating current suppression strategy[J]. Power system protection and control,2021,49(2):30-38.
- [6]李国庆,张林,江守其,等.风电经双极混合型MMCHVDC并网的直流故障穿越协调控制策略[J].电力系统保护与控制,2021,49(10):27-36.LI Guoqing,ZHANG Lin,JIANG Shouqi,et al. Coordinated control strategies for DC fault ride-through of wind power integration via bipolar hybrid MMC-HVDC overhead lines[J]. Power System Protection and Control,2021,49(10):27-36.
- [7] SONG G B,HOU J J,GUO B,et al.Pilot protection of hybrid MMC DC grid based on active detection[J].Protection and Control of Modern Power Systems,2020,5(1):1-15.
- [8]王思华,赵磊,王军军,等.基于MMC的直流输电系统双极短路故障保护策略研究[J].电力系统保护与控制,2021,49(11):9-17.WANG Sihua,ZHAO Lei,WANG Junjun,et al.Research on protection strategy of a bipolar short circuit fault in an HVDC transmission system based on MMC[J]. Power System Protection and Control,2021,49(11):9-17.
- [9] GUO G P,SONG Q,YANG W B,et al.Application of third-order harmonic voltage injection in a modular multilevel converter[J].IEEE Transactions on Industrial Electronics,2018,65(7):5260-5271.
- [10]荣飞,黄韬,饶宏,等.MMC换流阀最优三次谐波注入方法研究[J].高压电器,2019,55(7):20-26.RONG Fei,HUANG Tao,RAO Hong,et al. Optimal method of third harmonic injection to MMC value[J].High Voltage Apparatus,2019,55(7):20-26.
- [11]苑宾,梅念,陈东,等.三次谐波注入对MMC运行特性的影响[J].高电压技术,2020,46(3):1059-1067.YUAN Bin,MEI Nian,CHEN Dong,et al.Influences of third harmonic injection on the operation characteristics of MMC system[J].High Voltage Engineering,2020,46(3):1059-1067.
- [12]王庆,丁久东,刘海彬,等.MMC型柔性直流输电系统三次谐波注入调制策略的可行性[J].电力系统自动化,2018,42(17):104-110.WANG Qing,DING Jiudong,LIU Haibin,et al.Feasibility of third harmonic injection modulation strategy for MMC-HVDC transmission system[J]. Automation of Electric Power Systems,2018,42(17):104-110.
- [13]戴志辉,黄敏,苏怀波.基于MMC的环状直流配网在不同接地方式下的故障特性分析[J].电力系统保护与控制,2019,47(1):1-10.DAI Zhihui,HUANG Min,SU Huaibo.Analysis on fault characteristics of MMC-based ring DC distribution networks under different grounding modes[J].Power System Protection and Control,2019,47(1):1-10.
- [14]吴方劼,马玉龙,梅念,等.舟山多端柔性直流输电工程主接线方案设计[J].电网技术,2014,38(10):2651-2657.WU Fangjie,MA Yulong,MEI Nian,et al.Design of main connection scheme for Zhoushan flexible multi-terminal HVDC transmission project[J]. Power System Technology,2014,38(10):2651-2657.
- [15]秦桑.三次谐波注入应用于MMC-HVDC的研究[J].浙江电力,2015,34(7):5-9.QIN Sang.Study on application of third harmonic injection in MMC-HVDC[J]. Zhejiang Electric Power,2015,34(7):5-9.
- [16] CHEN J K,SUN C,LI Y,et al.The analysis of DC fault mode effects on MMC-HVDC system[C]//2017 IEEE Power&Energy Society General Meeting. Chicago,IL,USA.IEEE,2017:1-5.
- [17] LI G,LIANG J,MA F,et al.Analysis of single-phase-toground faults at the valve-side of HB-MMCs in HVDC systems[J].IEEE Transactions on Industrial Electronics,2019,66(3):2444-2453.
- [18] LU Y C,LIU T L,JIANG G G,et al. Research on the Fault Characteristics of DC side Based on MMC-HVDC[C]//2018 Chinese Automation Congress(CAC).Xi’an,China.IEEE,2018:520-525.
- [19] ZANG J J,WANG J C,ZHANG J W,et al.Grounding design and fault analysis of MMC based flexible interconnection device in future distribution networks[C]//2018IEEE International Power Electronics and Application Conference and Exposition(PEAC). Shenzhen,China.IEEE,2018:1-6.
- [20] XU X S,ZHAO Y M,WANG J,et al.Research on influence of AC neutral grounding impedance on common mode current of MMC flexible DC system[C]//202111th International Conference on Power and Energy Systems(ICPES).Shanghai,China.IEEE,2021:6-11.
- [21]刘思源,徐东旭,梅念,等.直流侧故障对模块化多电平换流器的影响研究[J].电力系统保护与控制,2017,45(10):48-54.LIU Siyuan,XU Dongxu,MEI Nian,et al. Research on the effect of DC side fault on modular multilevel converter[J].Power System Protection and Control,2017,45(10):48-54.
- [22]彭宇锋,张英敏,李俊松,等.考虑线路电容的MMCHVDC系统直流接地故障电流计算方法[J].电力系统保护与控制,2020,48(23):57-63.PENG Yufeng,ZHANG Yingmin,LI Junsong,et al.Ground fault current calculation method for an MMCHVDC system considering line capacitance[J].Power System Protection and Control,2020,48(23):57-63.
- [23]梅念,陈东,吴方劼,等.基于MMC的柔性直流系统接地方式研究[J].高电压技术,2018,44(4):1247-1253.MEI Nian,CHEN Dong,WU Fangjie,et al. Study on grounding methods for MMC-based VSC-HVDC systems[J].High Voltage Engineering,2018,44(4):1247-1253.
- [24]单节杉,任敏,田鑫萃,等.MMC换流站阀侧交流接地故障电流解析[J].电力系统保护与控制,2022,50(19):36-48.SHAN Jieshan,REN Min,TIAN Xincui,et al.Analysis of grounding fault current at the AC valve side of an MMC converter station[J]. Power System Protection and Control,2022,50(19):36-48.
- [25]韩子娇,高凯,王朝斌,等.无换流变MMC-HVDC的零序电流影响机理分析与抑制[J].电力系统保护与控制,2017,45(12):67-73.HAN Zijiao,GAO Kai,WANG Chaobin,et al. Zero sequence current effect mechanism analysis and suppression for the transformerless MMC-HVDC system[J]. Power System Protection and Control,2017,45(12):67-73.
- [26]喻锟,杨理斌,曾祥君,等.风电场集电线路单相接地故障柔性电压消弧与动态保护新原理[J].中国电机工程学报,2024,44(5):1789-1801.YU Kun,YANG Libin,ZENG Xiangjun,et al.A new principle of flexible voltage arc suppression and dynamic protection for single phase grounding faults of wind farm collector line[J]. Proceedings of the CSEE,2024,44(5):1789-1801.
- [27]周永荣,秦文康,葛佳盛,等.柔性直流配电系统换流器交流侧接地故障的分析[J].电力系统保护与控制,2020,48(19):160-167.ZHOU Yongrong,QIN Wenkang,GE Jiasheng,et al.Analysis of grounding fault on the AC side of converter station in a flexible DC distribution system[J].Power System Protection and Control,2020,48(19):160-167.
- [28]高校平,黄文焘,邰能灵,等.基于暂态电流的MMCLVDC双极短路故障定位方法[J].电力系统自动化,2020,44(17):127-135.GAO Xiaoping,HUANG Wentao,TAI Nengling,et al.Transient current based fault location method of pole-topole short-circuit for modular multilevel converter lowvoltage direct current[J]. Automation of Electric Power Systems,2020,44(17):127-135.
- [29]张芳,杜雪靓,陈堃.MMC-HVDC系统换流器桥臂短路故障暂态特性分析[J].电力自动化设备,2020,40(5):180-187.ZHANG Fang,DU Xuejing,CHEN Kun.Transient characteristic analysis of converter bridge arm short circuit fault in MMC-HVDC system[J].Electric Power Automation Equipment,2020,40(5):180-187.