浙江电力

2014, v.33;No.218(06) 43-47

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

采用离子色谱法检测电除尘飞灰中的氨含量
Application of Ion-Chromatography Method in Detecting Ammonia Content in Electrostatic Precipitator Fly Ash

周飞梅,曹志勇,汤治,郑志明,汪景婷
ZHOU Feimei,CAO Zhiyong,TANG Zhi,ZHENG Zhiming,WANG Jingting

摘要(Abstract):

根据离子色谱法检测电除尘飞灰中氨含量的原理,进行检测条件优化试验,得出影响飞灰中氨含量的主要因素有溶液pH值、搅拌时间、水灰比等。在得出最佳试验条件后,进行重复性测试和加标回收率测试,结果表明离子色谱法测定飞灰中氨含量的方法具有较高的精密度和准确度,可作为监测脱硝系统氨逃逸的一种手段。
By applying the principle of ion-chromatography method for testing ammonia content in electrostatic precipitator fly ash, tests to optimize detecting conditions is carried on. It is concluded that the main factors influencing ammonia content in fly ash are pH of solution, mixing time, water and ash ratio and so forth. After optimal test condition is obtained, repeatability test and adding standard recovery rate test are conducted.The results show that ion-chromatography method is of high precision and accuracy in testing ammonia content in electrostatic precipitator fly ash and it can be used to monitor ammonia escape in desulfurization system.

关键词(KeyWords): 离子色谱法;飞灰;氨逃逸量;脱硝系统
ion-chromatography method;fly ash;ammonia escape amount;desulfurization system

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 周飞梅,曹志勇,汤治,郑志明,汪景婷
ZHOU Feimei,CAO Zhiyong,TANG Zhi,ZHENG Zhiming,WANG Jingting

DOI: 10.19585/j.zjdl.2014.06.012

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享