尿素漏入引起机组水汽品质劣化的事故分析及处理Analysis and treatment of water-steam quality deterioration of generating units caused by urea leakage
徐兴宪
XU Xingxian
摘要(Abstract):
燃煤电厂实施液氨改尿素工程后,若尿素漏入机组水汽系统会产生水汽品质劣化现象。以一起因尿素漏入水汽系统导致1 000 MW机组非计划停运的事故为例,从事故现象、处理过程、排查分析过程、制定防范措施、诊断手段等方面展开论述。给水氢导电率异常升高是主要事故现象;通过分析给水氢导电率、铵离子与除盐水及凝结水TOCi含量关联变化的规律,找出事故原因是尿素漏入水汽系统;通过系统排查,找出源头是尿素站废水污染了发电厂原水。同时提出了预防尿素漏入的措施以及诊断尿素漏入的手段。
After the implementation of the liquid ammonia to urea conversion project in a coal-fired power plant, urea leakage into the steam-water system of unit may lead to deteriorated steam-water quality. With an unscheduled shutdown of a 1,000 MW unit due to urea leakage into water-steam system as an example, the accident phenomenon, treatment process, investigation and analysis process, formulation of precautionary measures, and diagnostic means are discussed. Abnormal increase of feedwater hydrogen conductivity is the main accident phenomenon.Through analysis the laws of correlation between feedwater hydrogen conductivity, ammonium ions and TOCi contents of demineralized water and condensate, it is determined that the accident is caused by leakage of urea into the water-steam system. The systematic investigation shows that the accident results fundamentally from the contamination of raw water in the power plant by wastewater from the urea station. Meanwhile, measures to prevent urea leakage into the water-steam system and means to diagnose urea leakage into the system are proposed.
关键词(KeyWords):
尿素制氨;水汽品质;氢电导率;事故分析
ammonia production from urea;water-steam quality;hydrogen conductivity;accident analysis
基金项目(Foundation):
作者(Author):
徐兴宪
XU Xingxian
DOI: 10.19585/j.zjdl.202310014
参考文献(References):
- [1]国家能源局.国能发安全21号文.电力行业危险化学品安全风险集中治理实施方案[Z].2022.
- [2]易文彬.燃煤电厂尿素制氨技术研究[J].能源与节能,2020(7):53-55.YI Wenbin. Study on ammonia production technology from urea in coal-fired power plant[J].Energy and Energy Conservation,2020(7):53-55.
- [3]国家质量监督检验检疫总局,中国国家标准化管理委员会.火力发电机组及蒸汽动力设备水汽质量:GB/T12145—2016[S].北京:中国标准出版社,2016.
- [4]国家能源局.火力发电厂水汽化学监督导则:DL/T 561—2013[S].北京:中国电力出版社,2014.
- [5]熊远南.尿素漏入对机组水汽品质的影响及关键诊断技术[J].工业水处理,2022,42(5):184-190.XIONG Yuannan.Effects of urea leakage into boiler thermodynamic system on steam-water quality and key techniques on diagnose its existence in coal power units[J].Industrial Water Treatment,2022,42(5):184-190.
- [6]李春芬,郑镇.锅炉除盐水系统中的有机物污染及处理方法[J].中国给水排水,2009,25(4):74-76.LI Chunfen,ZHENG Zhen.Organic pollution in boiler desalination water system and its treatment method[J].China Water&Wastewater,2009,25(4):74-76.
- [7]张燕,侯亚琴,刘国强,等.火电机组水汽系统总有机碳(TOC)检测与规律研究[J].华东电力,2014,42(4):757-760.ZHANG Yan,HOU Yaqin,LIU Guoqiang,et al. Detection and law of TOC in water and steam system in power plants[J]. East China Electric Power,2014,42(4):757-760.
- [8]刘玮,齐全友,胡兴,等.16台超超临界机组在线化学仪表运行现状调查和分析[J].中国电机工程学报,2021,41(3):1026-1035.LIU Wei,QI Quanyou,HU Xing,et al.Investigation and research on the operation status of on line chemical instruments for 16 ultra supercritical units[J].Proceedings of the CSEE,2021,41(3):1026-1035.
- [9]王娜娜,王锋涛,常亮,等.锅炉补给水中典型有机物分解规律及其对低压缸叶片腐蚀特性研究[J].中国腐蚀与防护学报,2017,37(6):597-604.WANG Nana,WANG Fengtao,CHANG Liang,et al.Decomposition of typical organic substance in water supply of boiler and corrosivity of its decomposition products[J].Journal of Chinese Society for Corrosion and Protection,2017,37(6):597-604.
- [10]李海洋,王仁雷,祁东东,等.供热工况下超临界机组水汽氢电导率异常研究分析[J].工业水处理,2020,40(4):113-116.LI Haiyang,WANG Renlei,QI Dongdong,et al. Study and analysis of supercritical unit’s abnormal hydrogen conductivity of water and vapor under heat addition[J].Industrial Water Treatment,2020,40(4):113-116.
- [11]徐洪.给水TOC对蒸汽氢电导率的影响[J].中国电机工程学报,2017,37(增刊1):129-136.XU Hong. Influence of feedwater TOC on steam cation conductivity[J].Proceedings of the CSEE,2017,37(S1):129-136.
- [12]张龙明,侯海军,刘玮,等.某供热机组水汽氢电导率异常波动及超标原因分析[J].工业水处理,2021,41(4):134-138.ZHANG Longming,HOU Haijun,LIU Wei,et al.Analysis on abnormal fluctuation and over-standard of cation conductivity of water vapor in a heat-supply unit[J].Industrial Water Treatment,2021,41(4):134-138.
- [13]张文耀,田文涛,治卿,等.总有机碳测定在火电厂水汽品质异常分析中的应用[J].中国电力,2020,53(5):150-154.ZHANG Wenyao,TIAN Wentao,ZHI Qing,et al.Application of total organic carbon measurements for abnormal WaterSteam quality analysis in thermal power plants[J].Electric Power,2020,53(5):150-154.
- [14]吕洪坤,杨卫娟,周俊虎,等.尿素溶液高温热分解特性的实验研究[J].中国电机工程学报,2010,30(17):35-40.LüHongkun,YANG Weijuan,ZHOU Junhu,et al.Investigation on thermal decomposition characteristics of urea solution under high temperature[J]. Proceedings of the CSEE,2010,30(17):35-40.
- [15]陈欢林,戴兴国,吴礼光.反渗透、纳滤膜技术脱除小分子有机物的研究进展[J].膜科学与技术,2009,29(3):1-10.CHEN Huanlin,DAI Xingguo,WU Liguang. Advances on removal of low-molecular-weight organics by reverse osmosis and nanofiltration[J]. Membrane Science and Technology,2009,29(3):1-10.
- [16]杜艳超.火力发电机组水汽氢电导率异常原因分析及处理[J].电力科技与环保,2020,36(3):24-26.DU Yanchao. Cause analysis and treatment of abnormal cation conductivity of water-vapor in thermal power generators[J].Electric Power Technology and Environmental Protection,2020,36(3):24-26.
- [17]潘珺,李杨,刘玮,等.总有机碳-离子色谱联用检测方法在发电厂有机物污染查定中的应用[J].湖北电力,2022,46(1):31-36.PAN Jun,LI Yang,LIU Wei,et al.Application of total organic carbon-ion chromatography in the determination of organic pollution in power plants[J]. Hubei Electric Power,2022,46(1):31-36.
- [18]毛进,李亚娟,刘亚鹏,等.MBR工艺中膜系统污染与堵塞的研究[J].中国电力,2016,49(1):44-48.MAO Jin,LI Yajuan,LIU Yapeng,et al. The study of membrane fouling in MBR[J]. Electric Power,2016,49(1):44-48.
- 尿素制氨
- 水汽品质
- 氢电导率
- 事故分析
ammonia production from urea - water-steam quality
- hydrogen conductivity