通过介绍燃煤锅炉控制烟气排放中CO含量的意义及重要性,分析各燃烧因素与烟气CO生成之间的相关影响,阐明要保证锅炉燃烧的高效率,取决于确定不同负荷工况下的合理送风量,将烟气中CO含量值控制在某一最佳范围内。通过对某发电厂2台机组在600 MW工况下的运行参数进行推导性测算,得出每台机组基于安全性和经济性角度考虑的CO含量合理控制值。
By introducing the meaning and significance of CO content control in flue gas emission of coalfired boiler, the paper analyzes the interaction between the combustion factors and generation of CO in flue gas. It is elaborated that high-efficient boiler combustion depends on reasonable air input under different load conditions and control of CO content in the optimal range. By derivation calculation of operation parameters of two 600 MW units in a power plant, the paper concluded the reasonable control value of CO content considering safety and efficiency of each unit.
关键词(KeyWords):
CO含量;氧量;燃烧调整;高温腐蚀;燃烧效率
CO content;oxygen amount;combustion adjustment;high temperature corrosion;combustion efficiency
基金项目(Foundation):
作者(Author):
刘季江,包海斌
LIU Jijiang,BAO Haibin
DOI: 10.19585/j.zjdl.201801012
参考文献(References):
- [1]李玉江,吴涛.德国燃煤电厂氮氧化物的控制技术[J].环境科学研究,2000,13(4):47-49.
- [2]黄伟珍.超超临界百万机组基于CO控制的锅炉燃烧优化调整[J].江西电力,2017(6):58-60.
- [3]要亚斌,徐倩.电站锅炉高温腐蚀原理分析与防护[J].河北电力技术,2011,30(3):41-43.
- [4]邓均慈.600 MW亚临界锅炉低氮改造后燃烧优化试验分析[J].广西电力,2014,37(3):82-85.
- [5]姚卫刚,韦红旗,何长征.660 MW四角切圆锅炉CO排放特性的试验研究[J].电站系统工程,2015,31(5):13-16.
- [6]ROBERT C.Molloy Dynatron,Inc.Microprocessor based combustion monitoring and control systems utilizing in SITU opacity,Oxygen,and CO measurement(Energy Conservation Systems)[G].Wallingford,Connecticut.
- [7]KAULITZ J.Optimierung von Dampferzeuger and Rauchgas-reinigungsanlagen[J].VGB Kraftwerks technik,1990,80(10):862-868.
- [8]周平,张广才,严晓勇.600 MW机组对冲燃煤锅炉尾部CO浓度偏高的调整试验[J].热力发电,2014,43(12):82-88.
- [9]周杨军.420 t/h锅炉低氮燃烧改造与运行优化调整[J].浙江电力,2015,34(3):40-43.
- [10]宁献武,李志山,李树民,等.1 000 MW机组锅炉燃烧调整与经济运行[J].热力发电,2012,41(3):51-54.
- [11]张俊伟.基于CO信号的燃烧控制在火电厂的研究和应用[J].科技与管理,2017(5):108-109.
- [12]裘立春,张建华.基于CO的燃煤锅炉燃烧优化[J].浙江电力,2005,24(3):10-12.
- [13]卢毓东,谢宏海,陆建伟.烟气排放连续监测系统数据异常的分析及处理[J].浙江电力,2012,31(11):34-37.
- [14]龚和,刘安堂,方晓东,等.600 MW超临界机组锅炉燃烧优化调整方法[J].华东电力,2010,38(9):1463-1465.
- [15]齐晓娟,童家麟,吕洪坤,等.1 000 MW超超临界机组锅炉生物质与煤粉混烧数值模拟研究[J].浙江电力,2017,36(5):29-33.
- [16]潘存华,彭荣,李德.600 MW机组对冲燃烧锅炉运行问题分析及解决[J].巢湖学院学报,2014,16(6):104-107.
- [17]章良利,李敏,赵敏,等.对冲燃烧锅炉低氮燃烧器改造后煤种适应性试验研究[J].浙江电力,2016,35(11):37-41.
- [18]李德波,沈跃良,余岳溪,等.旋流燃烧煤粉锅炉主要烟气组分及分布规律试验[J].广东电力,2016,29(3):1-7.
- CO含量
- 氧量
- 燃烧调整
- 高温腐蚀
- 燃烧效率
CO content - oxygen amount
- combustion adjustment
- high temperature corrosion
- combustion efficiency