浙江电力

2016, v.35;No.242(06) 38-41

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

火电厂在役管道支吊架性能的测试研究
Research on Performance Test of In-service Pipe Hangers and Supports in Thermal Power Plant

刘明,陈锐,何桂宽
LIU Ming,CHEN Rui,HE Guikuan

摘要(Abstract):

支吊架性能对火电厂管道安全运行有重要影响,结合相关规范对支吊架性能的要求,对比2种支吊架性能测试方法的优缺点,针对在役支吊架的工作特点,建立了采用粘贴应变片间接获得吊架性能参数的测试系统,并成功应用于某600 MW超超临界机组相关支吊架的性能测试,为同类型支吊架的性能测试提供了可供参考的经验。
The performance of hangers and supports is key to pipe operation safety in thermal power plant. In accordance with requirements of relevant specifications on the performance of hangers and supports, advantages and disadvantages of two hangers and supports performance test methods are compared. Based on operation characteristics of in-service hangers and supports, a test system that indirectly obtains performance parameters of hangers and supports by strain gauge pasting is developed and successfully used for performance test of hangers and supports of 600 MW ultra-supercritical units, providing experience for performance test of supports and hangers with the same type.

关键词(KeyWords): 管道;支吊架;性能测试;应变片
pipe;support and hanger;performance test;strain gauge

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 刘明,陈锐,何桂宽
LIU Ming,CHEN Rui,HE Guikuan

DOI: 10.19585/j.zjdl.2016.06.009

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享