绝缘液带电清洗二次设备表面污秽技术的研究及应用Application and Research of the Technology of Contamination Cleaning on Secondary Equipment Surface with Insulating Liquid
龚先鹤,王臻,易永利,周杰
GONG Xianhe,WANG Zhen,YI Yongli,ZHOU Jie
摘要(Abstract):
针对变电站内二次设备清扫难的问题,对BU-666绝缘液带电清洗二次设备表面污秽技术的效果进行了试验研究,通过偏光显微镜下的微观角度记录各个设备的清洗结果,分别测量它们的表面电阻,并绘制相应的清洗效果数值图和效率数值图,发现装置板件和继电器清洗效果最好。结合清洗实时漏电流数据,计算清洗过程中二次回路各个设备的对地绝缘电阻。试验及现场应用结果表明:BU-666绝缘液带电清洗二次设备污秽技术效果显著,带电清洗过程不影响二次设备的正常运行。
In view of the difficulty of secondary equipment cleaning in substations, the effect of live contamination cleaning on secondary equipment surface by using BU-666 insulating liquid is tested and investigated.By records of cleaning result of the equipment through micro perspective under polarizing microscope, surface resistances of the equipment are measured, and the cleaning effect and efficiency are charted. It is found that the plates and relays are best cleaned. Based on the real-time leakage current data, ground insulation resistance of secondary circuit equipment in the cleaning process is calculated. The test and field application show that live contamination cleaning of secondary equipment with BU-666 insulating liquid is effective and has no effect on the operation of secondary equipment.
关键词(KeyWords):
绝缘液;漏电流;二次回路;带电清洗
insulating liquid;leakage current;secondary circuit;live cleaning
基金项目(Foundation):
作者(Author):
龚先鹤,王臻,易永利,周杰
GONG Xianhe,WANG Zhen,YI Yongli,ZHOU Jie
DOI: 10.19585/j.zjdl.2017.02.002
参考文献(References):
- [1]郑翠红.浅谈通讯设备的污染与带电清洗[J].信息通信,2011(6):147-148.
- [2]章志昕,叶青,来佳磊.高频电源在静电除尘器上的应用[J].浙江电力,2016,35(1):57-60.
- [3]韩桂芹.变电站二次设备带电清洗关键点及溶剂性能分析[J].无线互联网科技,2009,42(7):80-83.
- [4]孙卫庆,张鹰,楼平.通信设备带电清洗技术探讨[J].浙江电力,2010,29(4):38-42.
- [5]张力.浅谈通讯设备清洗与静电平衡维护[J].新技术新业务,2001(2):72-74.
- [6]李少白,吕红峰,叶志康,等.500 kV变电设备带电水冲洗方法的研究[J].浙江电力,2015,34(9):25-28.
- [7]刘新平.带电水冲洗变电设备的开展庆与注意事项[J].上海电力,2003,35(2):120-122.
- [8]GB 13395-2008电力设备带电水冲洗规程[S].北京:中国标准出版社,2008.
- [9]GB/T 14545-2003带电作业小水量冲洗工具[S].北京:中国标准出版社,2003.
- [10]朱国梅,网旭明.电器设备清洗剂的品质及组成浅析[J].清洗世界,2006,22(11):44-47.