配电网低压故障检测仪的设计及应用Design and application of Fault Detector for Low-voltage System of Distribution Network
潘亦辰,周国良,贾斌
PAN Yichen,ZHOU Guoliang,JIA Bing
摘要(Abstract):
介绍了配电网低压系统常见故障及相应处理方法,指出传统的排除试送法和兆欧表检测法存在弊端。针对上述问题,设计研制了能够模拟工频交流电并将之作为检测信号的故障检测仪,介绍了检测仪的工作原理、电路设计、整体结构,通过实验室验证及现场使用,表明该故障检测仪可以解决配电网隐性故障排查的难题。
The paper introduces common faults in LV system of distribution networks and the corresponding handling methods. Besides, the paper indicates that there are disadvantages in traditional trial energization method and Megger detection method. Therefore, a fault detector that can simulate power-frequency alternate current and take it as detection signal is designed and developed. The paper introduces work principle, circuit design, and overall structure of the detector. Through verification in lab and field application, it is shown that the detector can help potential fault detection in distribution networks.
关键词(KeyWords):
配电网;故障检测仪;隐性故障;短路;漏电
distribution network;fault detector;potential fault;short circuit;current leakage
基金项目(Foundation):
作者(Author):
潘亦辰,周国良,贾斌
PAN Yichen,ZHOU Guoliang,JIA Bing
DOI: 10.19585/j.zjdl.2016.07.017
参考文献(References):
- [1]李瑞.220/380 V低压配电网故障解析及解决方案[J].中国高新技术企业,2014(32):37-39.
- [2]刘石生.影响0.4 k V配网供电可靠性的原因分析及措施探讨[C]//2010年全国电力系统配电技术协作网第三届年会论文集.佛山,2010:733-736.
- [3]杨静华,张丽敏.小型变压器的设计[J].农机化研究,2003(2):231-232.
- [4]汤继东.低压配电常见问题分析[M].北京:中国电力出版社,2006.
- [5]金备.浅谈城市中、低压配电网的结构[C]//面向21世纪电力可持续发展学术研讨会论文集.西安,1999:86-90.
- [6]郑百君.操作面板布局设计的原则[J].自动化信息,2010(3):72-74.
- [7]MITSUHARU KOMODA,MITSUGU AIHARA.Development of Current Detection Type Cable Fault Location.IEEE Transactions on Power Delivery,1991,6(2).
- [8]李建辉.电力电缆故障检测方法与应用[J].河北电力技术,2009,28(3):36-38.
- [9]杜东威,许永军,金红卫.一种基于DTU的配电网单相接地故障检测和定位方法[J].浙江电力,2015,34(3):1-5.
- [10]朱建宝,刘建平.10 k V线路故障指示器单相接地故障检测原理分析[J].电气应用,2015,34(4):93-96.
- [11]李电元,刘伟.低压配电网多支路电缆带电识别装置的设计[J].哈尔滨商业大学学报(自然科学版),2012,28(2):228-230.
- [12]李文才,闫铁芳.基于区域的树状配电网故障自动定位系统研究[J].浙江电力,2008,27(6):17-19.
- [13]吕圣宏.10 k V配电线路单相接地故障检测及处理方法[J].电子技术与软件工程,2014(10):173.