S106B燃气-蒸汽联合循环机组热力性能试验分析Performance Test for S106B Gas-steam Combined-cycle Unit
王克勤,金晓刚
摘要(Abstract):
文章介绍了金华燃机电厂联合循环机组热力性能试验的情况 ,通过对试验数据的计算分析并结合生产实践探讨了S106B联合循环机组AGC限值的关键技术问题
This paper introduces the performance test of S106B combined cycle unit in Jinhua gas turbine power plant.By analysing this test and combining with the practice,the key points of the AGC limitation for S106B unit output are discussed.
关键词(KeyWords):
联合循环;性能试验;计算分析;AGC限值
combined cycle;performance test;calculating and analysing;AGC limitation of output