HMB-4型液压弹簧操作机构频繁打压故障的现场检修On-Site Maintenance of Frequent Pressurizing for HMB-4 Hydraulic-Spring Operating Mechanism
韩筱慧,闻飞翔,费宇,卞寅飞,王彪,姚继星
HAN Xiaohui,WEN Feixiang,FEI Yu,BIAN Yinfei,WANG Biao,YAO Jixing
摘要(Abstract):
HMB-4型液压弹簧操作机构因其结构紧凑、可靠性高、传动效率高等优点,逐渐得到广泛应用,但与其他型号的液压操作机构相比,现场检修经验缺乏。以国网浙江省电力公司嘉兴供电公司一起HMB-4型液压弹簧操作机构频繁打压故障的现场消缺为例,通过对频繁打压故障原因的分析,以现场实际检修经验为依据,总结该型号操作机构频繁打压故障的现场检修策略,为今后现场检修提供依据。
Due to the advantages of compact structure, high reliability, high transmission efficiency, the HMB-4 hydraulic-spring operating mechanism has been widely used gradually. But compared with other hydraulic operating mechanisms, the on-site maintenance experience for HMB-4 is deficient. The paper takes the case of on-site maintenance experience of frequent pressurizing for HMB-4 hydraulic-spring operating mechanism by the State Grid Jiaxing Power Supply Company as an example and analyzes the reasons of frequent pressurizing, based on which and on-site maintenance experience, the paper summarizes on-site maintenance strategy, providing bases for on-site maintenance of the mechanism in the future.
关键词(KeyWords):
HMB-4;操作机构;频繁打压;现场检修
HMB-4;operating mechanism;frequent pressurizing;on-site maintenance
基金项目(Foundation):
作者(Author):
韩筱慧,闻飞翔,费宇,卞寅飞,王彪,姚继星
HAN Xiaohui,WEN Feixiang,FEI Yu,BIAN Yinfei,WANG Biao,YAO Jixing
DOI: 10.19585/j.zjdl.2015.04.019
参考文献(References):
- [1]朱素萍.高压断路器及其操作机构事故原因分析和处理[J].中国高新技术企业,2007,14(7):72-73.
- [2]巫环科,陈永佳.500 k V HGIS液压操作机构打压频繁的分析及对策[J].高压电器,2012,47(2):119-122.
- [3]郑雷.液压机构油泵频繁启动原因分析及对策[J].高压电器,2010,46(7):85-89.
- [4]李建明,王志勇,王叔琛.3AQ/3AT型断路器液压机构油泵频繁打压故障分析及处理方法[J].高压电器,2011,47(5):103-107.
- [5]韦斌.SF6断路器异常打压原因分析及解决方法[J].南方电网技术,2008,2(6):96-98.
- [6]许杨,刘之奎,潘丰峰.HMB-4/8型开关弹簧液压操作机构频繁打压故障原因[J].东北电力技术,2010(1):50-52.
- [7]陈保伦.HMB-4型液压弹簧机构的特点、操作使用及故障处理[J].电气制造,2009(5):66-69.