避雷器在线监测仪水平平台的研制Development of Horizontal Platform for On-line Arrester Monitoring Device
周天宇,殷文宣,凌秋阳,陈昱
ZHOU Tianyu,YIN Wenxuan,LING Qiuyang,CHEN Yu
摘要(Abstract):
为解决避雷器在线监测仪试验时所处平台水平度对试验误差大的问题,研制了一种新型避雷器在线监测仪试验用水平平台,通过试验数据说明了该平台能降低变电所现场试验避雷器在线监测仪的误差,同时还能使避雷器在线监测仪更换工作更加标准化、规范化,提高了作业效率。
To eliminate the error caused by the horizontal platform level in online arrester monitoring device test, a new horizontal platform for online arrester monitoring device test is developed. It is shown by the experimental data that the platform can not only reduce the influence of the error of the substation field test of on-line arrester monitoring device but also make the on-line arrester monitoring device replacement work more standardized and normalized to improve operation efficiency.
关键词(KeyWords):
避雷器;监测仪;试验;平台
arrester;monitoring device;test;platform