摘要(Abstract):
串补电容的接入将改变线路的序网络阻抗及故障后的序电流分布,虽然对串补电容安装侧选相元件无不利影响,但可能会导致对侧选相元件误选相。为此,提出一种基于线模相电流的故障选相方法。首先,将线模相电流定义为各相故障分量电流与零序电流之差;然后,分析不同故障类型下线模相电流的特征,提取故障相与非故障相的特征差异,从而构造选相判据;最后,基于PSCAD平台进行仿真验证,结果表明,所提方法能够准确识别串补线路的故障相别,且其性能不受故障位置、线路长度、串补补偿度等因素的影响。
The connected series-compensated capacitors alter the sequence network impedance of transmission lines and the distribution of sequence currents during faults. While this does not adversely affect the phase-selection elements on the capacitor installation side, it may lead to misidentification by those on the opposite side. To address this, a fault phase selection method based on line-mode phase current is proposed. First, the line-mode phase current is defined as the difference between the fault-component current of each phase and the zero-sequence current. Next, the characteristics of line-mode phase currents under different fault types are analyzed to extract distinctions between faulted and non-faulted phases, from which the phase-selection criterion is constructed. Finally, the method is validated through simulations on the PSCAD platform. The results show that the proposed method can accurately identify the faulted phase in series-compensated transmission lines, and its performance is robust with respect to fault location, line length, and the degree of series compensation.
关键词(KeyWords):
输电线路;故障选相;串补电容;故障分量;序分量
transmission lines;fault phase selection;series-compensated capacitor;fault components;sequence components
基金项目(Foundation): 国家电网公司总部科技项目(5108-202218280A-2-276-XG)
作者(Author):
杨黎明,谢诗敏,王仲,陈福锋,薛明军,陈中
YANG Liming,XIE Shimin,WANG Zhong,CHEN Fufeng,XUE Mingjun,CHEN Zhong
DOI: 10.19585/j.zjdl.202603007
参考文献(References):
- [1]RAI D,FARIED S O,RAMAKRISHNA G,et al.Hybrid series compensation scheme capable of damping subsynchronous resonance[J].IET Generation,Transmission&Distribution,2010,4(3):456-466.
- [2]李鹏,刘玢岩,习伟,等.基于模型参数辨识的串联补偿输电线路纵联保护原理[J].电力系统保护与控制,2022,50(22):20-28.LI Peng,LIU Binyan,XI Wei,et al.Pilot protection principle based on model parameter identification for a series compensated transmission line[J].Power System Protection and Control,2022,50(22):20-28.
- [3]NAYAK P K,PRADHAN A K,BAJPAI P.A fault detection technique for the series-compensated line during power swing[J].IEEE Transactions on Power Delivery,2013,28(2):714-722.
- [4]NAYAK P K,PRADHAN A K,BAJPAI P. Wide-area measurement-based backup protection for power network with series compensation[J].IEEE Transactions on Power Delivery,2014,29(4):1970-1977.
- [5]陈福锋,钱国明,薛明军.适用于串联电容补偿线路的距离保护新原理[J].电力系统自动化,2010,34(12):61-66.CHEN Fufeng,QIAN Guoming,XUE Mingjun.Research on new principle of distance protection adapted to series capacitor compensated line[J]. Automation of Electric Power Systems,2010,34(12):61-66.
- [6]王育学,尹项根,张哲,等.基于参数识别原理的串补线路距离保护[J].电力系统自动化,2011,35(14):98-102.WANG Yuxue,YIN Xianggen,ZHANG Zhe,et al.Distance protection for series compensated lines based on parameter identification principle[J].Automation of Electric Power Systems,2011,35(14):98-102.
- [7]黄宗超,王帆,刘一民,等.基于串补线性化模型的含串补线路距离保护整定方法[J].电力自动化设备,2019,39(11):133-138.HUANG Zongchao,WANG Fan,LIU Yimin,et al.Distance protection setting method for lines with series compensation based on series compensation linearization model[J]. Electric Power Automation Equipment,2019,39(11):133-138.
- [8]唐萃,尹项根,戚宣威,等.大串补度输电线路的电流差动保护分析与对策[J].电力系统自动化,2015,39(7):157-163.TANG Cui,YIN Xianggen,QI Xuanwei,et al. Analysis and countermeasures of current differential protection for large series compensation transmission lines[J].Automation of Electric Power Systems,2015,39(7):157-163.
- [9]李振兴,包文亮,陈艳霞,等.适用于含串补设备的输电线路电流差动保护新判据[J].电力系统保护与控制,2021,49(5):11-19.LI Zhenxing,BAO Wenliang,CHEN Yanxia,et al.A new criterion for current differential protection of transmission lines with series compensation equipment[J].Power System Protection and Control,2021,49(5):11-19.
- [10]HE S E,SUONAN J,BO Z Q. Integrated impedancebased pilot protection scheme for the TCSC-compensated EHV/UHV transmission lines[J].IEEE Transactions on Power Delivery,2013,28(2):835-844.
- [11]索南加乐,谈树峰,何世恩,等.基于模型识别的串补线路方向元件[J].电力系统自动化,2009,33(14):66-70.TAN Shufeng,HE Shien,et al.Directional element of series compensation line based on model identification[J].Automation of Electric Power Systems,2009,33(14):66-70.
- [12]许庆强,索南加乐,宋国兵,等.一种电流故障分量高压线路保护选相元件[J].电力系统自动化,2003,27(7):50-54.XU Qingqiang,XU Qingqiang,SONG Guobing,et al.Phase selection element for high-voltage line protection with current fault component[J]. Automation of Electric Power Systems,2003,27(7):50-54.
- [13]马静,王希,王增平.一种基于电流突变量的故障选相新方法[J].中国电机工程学报,2012,32(19):117-124.MA Jing,WANG Xi,WANG Zengping. A new fault phase identification method based on phase current difference[J]. Proceedings of the CSEE,2012,32(19):117-124.
- [14]徐振宇,杨奇逊,刘万顺,等.一种序分量高压线路保护选相元件[J].中国电机工程学报,1997,17(3):214-216.XU Zhenyu,YANG Qixun,LIU Wanshun,et al. A sequence fault phase selector for transmission line protective relay[J].Proceedings of the CSEE,1997,17(3):214-216.
- [15]黄少锋,申洪明,费彬.交直流互联系统对电流选相元件的影响分析及对策[J].华北电力大学学报(自然科学版),2016,43(2):1-7.HUANG Shaofeng,SHEN Hongming,FEI Bin. The effect of AC/DC interconnected network on the phase selector based on current and the countermeasure[J].Journal of North China Electric Power University(Natural Science Edition),2016,43(2):1-7.
- [16]李一泉,屠卿瑞,陈桥平,等.大型光伏电站对送出线路保护选相元件的影响[J].电网技术,2018,42(9):2976-2982.LI Yiquan,TU Qingrui,CHEN Qiaoping,et al.Influence of large-scale photovoltaic power plant on phase-selection elements of line protections[J]. Power System Technology,2018,42(9):2976-2982.
- [17]郎学毅,汤亚芳,熊炜,等.适应于逆变型风电接入系统的改进故障序分量选相方法[J].电力系统保护与控制,2024,52(7):89-97.LANG Xueyi,TANG Yafang,XIONG Wei,et al. Improved fault sequence component phase selection method suitable for inverter wind power access system[J].Power System Protection and Control,2024,52(7):89-97.
- [18]陈实,邰能灵,范春菊,等.逆变型电源接入对选相元件的影响分析[J].电力系统自动化,2017,41(12):106-112.CHEN Shi,TAI Nengling,FAN Chunju,et al.Influence of inverter-interfaced generator on element of phase selectors[J].Automation of Electric Power Systems,2017,41(12):106-112.
- [19]王晨清,宋国兵,汤海雁,等.选相及方向元件在风电接入系统中的适应性分析[J].电力系统自动化,2016,40(1):89-95.WANG Chenqing,SONG Guobing,TANG Haiyan,et al.Adaptability analysis of phase selectors and directional relays in power systems integrated with wind farms[J].Automation of Electric Power Systems,2016,40(1):89-95.
- [20]李振兴,杨梓康,杨桄,等.大规模新能源送出线路继电保护关键技术探讨[J/OL].浙江电力,2025:1-17.(2025-06-27)[2025-07-27].https://kns.cnki.net/KCMS/detail/detail. aspx filename=ZJDL20250624001&dbname=CJFD&dbcode=CJFQ.LI Zhenxing,YANG Zikang,YANG Guang,et al. Key technologies for relay protection of bulk renewable energy transmission lines[J/OL].Zhejiang Electric Power,2025:1-17.(2025-06-27)[2025-07-27]. https://kns. cnki. net/KCMS/detail/detail.aspx filename=ZJDL20250624001&dbname=CJFD&dbcode=CJFQ.
- [21]张俊峰,高亮,沈奕菲,等.适用于双馈机组风电场的故障电压序分量选相元件[J].电力系统保护与控制,2018,46(10):136-143.ZHANG Junfeng,GAO Liang,SHEN Yifei,et al.Faultsequence element of voltage phase selection applied to DFIG-based wind farm[J].Power System Protection and Control,2018,46(10):136-143.
- [22]崔超奇,王占山,杨东升,等.基于小波变换的输电线故障定位与选相方法[J].控制工程,2017,24(增刊1):85-91.CUI Chaoqi,WANG Zhanshan,YANG Dongsheng,et al.Approach of fault location and fault-phase selection for transmission lines with wavelet transform[J].Control Engineering of China,2017,24(S1):85-91.
- [23]田书,刘芳芳,任晓明.基于暂态量的同塔双回线路故障选相研究[J].电力系统保护与控制,2015,43(1):50-54.TIAN Shu,LIU Fangfang,REN Xiaoming. Research on transient-based faulty phase selection for double-circuit lines on the same tower[J].Power System Protection and Control,2015,43(1):50-54.
- [24]吴峰,郑建勇,梅军,等.基于可控串补的故障限流器[J].电网技术,2012,36(2):53-57.WU Feng,ZHENG Jianyong,MEI Jun,et al.Theoretical study and simulation of TCSC based fault current limiter[J].Power System Technology,2012,36(2):53-57.
- 输电线路
- 故障选相
- 串补电容
- 故障分量
- 序分量
transmission lines - fault phase selection
- series-compensated capacitor
- fault components
- sequence components