某台350MW双水内冷汽轮发电机组振动异常处理及分析Treatment and Analysis on Abnormal Vibration of the 350 MW Turbo-Generator with Double Inner Water-cooling
李卫军,吴文健,蔡文方
LI Weijun,WU Wenjian,CAI Wenfang
摘要(Abstract):
双水内冷发电机转子因冷却水管不同程度的堵塞引起轴振爬升的现象时有发生,常用的处理方法为停机进行反冲洗,但现场动平衡也可作为一种有效减振方法。通过一台350 MW发电机转子振动异常的测试,得出振动爬升的主因为转子部分冷却水管流动不畅产生了热弯曲,采用动平衡大幅降低其振动,确保了机组安全稳定运行。
The vibration of generator rotor shaft increases frequently due to blockage of the cooling water pipes of turbo-generator with double inner water-cooling.The common treatment is backwash during its shutdown;in addition,on-site dynamic balancing can be used to reduce the vibration.Through abnormal vibration testing of a 350 MW generator rotor,it is concluded that the main reason for the vibration increase is thermal bending due to some blocked cooling water pipes.It can ensure units operation safety and stability by using the dynamic balancing to reduce its vibration greatly.
关键词(KeyWords):
发电机;双水内冷;振动;动平衡
generator;double internal water-cooling;vibration;dynamic balancing
基金项目(Foundation): 国家自然科学基金资助项目(51275452);; 国网浙江省电力公司科技项目(5211DS14005B)
作者(Author):
李卫军,吴文健,蔡文方
LI Weijun,WU Wenjian,CAI Wenfang
DOI: 10.19585/j.zjdl.2017.01.012
参考文献(References):
- [1]胡磊,袁益超,李立军,等.300 MW双水内冷汽轮发电机定子铁心内空气流动特性研究[J].上海理工大学学报,2014(5):456-460.
- [2]关玉芳,楼新明,冯礼奎.发电机定子线棒堵塞治理与定冷水水质优化[J].浙江电力,2012,31(3):31-34.
- [3]卢洪坤,何朝晖,王建松.300 MW发电机定子绕组温差大缺陷分析及处理[J].浙江电力,2012,31(6):44-45.
- [4]寇胜利.汽轮发电机组的振动及现场平衡[M].北京:中国电力出版社,2007.
- [5]杨建刚.旋转机械振动分析与工程应用[M].北京:中国电力出版社,2007.
- [6]周怀里.双水内冷发电机转子回路堵塞原因分析和防止措施[J].江苏电机工程,2004(9):59-61.