摘要(Abstract):
基于OpenDSS仿真平台,结合国内某园区电网的高密度分布式光伏发电系统,针对光伏逆变器的恒功率因数、变功率因数和电压无功控制3种控制策略进行精细建模,搭建了含变电站AVC(自动电压控制)系统的园区电网详细仿真模型,在此基础上开展了园区电网全天的系统连续控制仿真。通过仿真分析,比较了各控制策略的有效性及其对现有AVC系统的影响,验证了无功电压控制策略的有效性和经济性,可为大量分布式光伏并网后的配电网规划与运行调度提供科学的参考依据,从而保障光伏的安全消纳。
Based on OpenDSS simulation platform and in accordance with dense distributed PV generation systems in power grid of a park zone in China, constant power factor, variable power factor and var-voltage control of PV inverter are modeled, and simulation model of park zone power grid with substation AVC(automatic voltage control) is established. Besides, system control and simulation on power grid are conducted all day long. By simulation analysis, the effectiveness of various control strategies are compared and their impact on AVC, and effectiveness and economic efficiency of var-voltage control strategy are verified to provide scientific reference basis for distribution network planning and operation scheduling with the integration of massive distributed PV and guarantee safe consumption of PV.
关键词(KeyWords):
分布式光伏;控制策略;AVC;OpenDSS
distributed PV;control strategies;AVC;OpenDSS
基金项目(Foundation): 国网浙江省电力有限公司科技项目(5211DS17002M)
作者(Author):
周金辉,骆宗义,王子凌,马振宇,张岩
ZHOU Jinhui,LUO Zongyi,WANG Ziling,MA Zhenyu,ZHANG Yan
DOI: 10.19585/j.zjdl.201810004
参考文献(References):
- [1]ARI G K,BAGHZOUZ Y.Impact of High PV Penetration on Voltage Regulation in Electrical Distribution Systems[J].IEEE,2011:744-748.
- [2]范元亮,赵波,江全元,等.过电压限制下分布式光伏电源最大允许接入峰值容量的计算[J].电力系统自动化,2012,36(17):40-44.
- [3]LAI J,YU W S,KATHLEEN M,et al.Distribution Modeling and Laboratory Verification of Power Conditioning[R].Blacksburg,Virginia:Department of Energy,2012.
- [4]BARRY M,BENJAMIN K,THOMAS E.Hoff,et al.Southern California Edison High-Penetration Photovoltaic Pro ject-Year 1[R].Golden,Colorado:U.S.Department of Energy,2011.
- [5]BANK J,MATHER B,KELLER J,et al.High Penetration Photovoltaic Case Study Report[R].Golden,Colorado:U.S.Department of Energy,2011.
- [6]LIU Y,BEBIC J,KROPOSKI B,et al.Distribution System Voltage Performance Analysis for High-Penetration PV[C].IEEE Energy 2030,Atlanta,Georgia,USA,17-18 November,2008.
- [7]REINALDO T,DAVE T,Tarek H.M.EL-Fouly.Impact of High PV Penetration on Voltage Profiles in Residential Neighborhoods[J].IEEE Trans on Sustainable Energy,2012,3(3):518-527.
- [8]许晓艳,黄越辉,刘纯,等.分布式光伏发电对配电网电压的影响及电压越限的解决方案[J].电网技术,2010,34(10):140-146.
- [9]崔红芬,汪春,叶季蕾.多接入点分布式光伏发电系统与配电网交互影响研究[J].电力系统保护与控制,2015,43(10):91-97.
- [10]寇凤海,朱晓荣,段晓波,等.光伏电源对配电网电压影响的逐时模拟[J].电力科学与工程,2011,27(3):5-9.
- [11]裴玮,孔力,齐智平.光伏发电参与配电网电压调节的控制策略研究[J].太阳能学报,2011,32(11):1629-1635.
- [12]赵悦,顾军,傅强.参与配电网电压调节的分布式光伏发电系统新型控制策略[J].广东电力,2016,29(12):45-49.
- [13]周金辉,盛晔,苏义荣,等.含高比例光伏的配电网电压协调控制策略研究[J].浙江电力,2018,37(4):7-13.
- [14]张颖,季宇,唐云峰.基于MPC含分布式光伏配电网有功功率-无功功率协调控制[J].电力系统自动化,2017,41(21):140-146.
- [15]肖传亮,赵波,周金辉.配电网中基于网络分区的高比例分布式光伏集群电压控制[J].电力系统自动化,2017,41(21):147-154.
- [16]罗煜,吴杰康,简俊威,等.基于机会约束规划的多类型分布式电源容量与布点优化方法[J].广东电力,2018,31(4):34-42.
- [17]余立武,李浩然,刘岩.考虑分布式电源出力随机性的配电网无功优化策略[J].电网与清洁能源,2017,33(12):91-98.
- [18]马经纬,王晓梅,陈淼,等.基于多智能体系统的智能微网分散协调控制策略[J].电网与清洁能源,2017,33(11):15-23.
- [19]葛浩天,张新慧.基于分布式清洁电源系统的微电网聚合模型[J].电网与清洁能源,2017,33(8):125-131.
- [20]王立斌,赵佩,王杉杉.基于离群点分析的分布式光伏发电量异常检测算法[J].电力大数据,2018,21(2):13-17.