浙江电力

2020, v.39;No.287(03) 1-7

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

一种应用于线路保护装置的嵌入式行波测距方法
A Method of Embedded Traveling Wave Fault Location for Line Protection Device

高小全,刘宏君,俞伟国,潘军军
GAO Xiaoquan,LIU Hongjun,YU Weiguo,PAN Junjun

摘要(Abstract):

在分析阻抗法测距技术与行波测距技术优缺点的基础上,提出一种新的嵌入式行波测距方法。通过将行波测距模块化,并以独立插件方式集成到线路保护装置中,既实现了完整的线路保护功能,还实现了完整的行波测距功能。并且行波测距模块复用线路保护装置的电流采样通道、光纤通信通道,共享线路保护故障数据与行波测距数据,提高了行波测距的准确性。
The advantages and disadvantages of impedance fault location technology and travelling wave fault location technology are introduced, and a new embedded travelling wave fault location method is presented.By modularization of travelling wave fault location and its integration into a line protection device as an independent plug-in, the overall line protection function and travelling wave fault protection are implemented. Besides, the travelling wave fault location modular employs current sampling channel and optical fibre communication channel and shares line protection fault data and travelling wave fault location data, improving the preciseness of travelling wave fault location.

关键词(KeyWords): 行波测距;阻抗法测距;线路保护;模块化
travelling wave fault location;impedance fault location;line protection;modularization

Abstract:

Keywords:

基金项目(Foundation): 国家电网有限公司华中分部重点科技项目(SGHZ0000DKJS1800137)

作者(Author): 高小全,刘宏君,俞伟国,潘军军
GAO Xiaoquan,LIU Hongjun,YU Weiguo,PAN Junjun

DOI: 10.19585/j.zjdl.202003001