摘要(Abstract):
探讨了放电线圈跨接在电容器与串联电抗器两端的可行性,理论分析和数值计算证明放电线圈的这种跨接并不影响电容器回路的放电特性,且有利于放电线圈的安全运行和产品型号规格的简化。同时,还指出在采用相差动保护的电容器线和需要直接检测电容器端电压的场合,放电线圈不能使用跨接方式。
This paper discusses a feasibility of electric discharge soils crossover capacitor and series reactor.Proof of theoretical analysis and value computation,this bridging does not affect flashover characteristic of capacitor.Also,it is advantageous to the electric discharge coil safe opˉeration and reduction of product model.Simultaneously,it also pointed out the electric discharge coil cannot across where differential protection is used in condenser bank,as well as the capacitor terminal voltage is exanined directly.