摘要(Abstract):

对2例安装不当导致的电涡流传感器的工作异常情况进行分析,介绍了安装空间以及被测导体特性对电涡流传感器测量的影响,并提出相关建议,以供参考。
Based on two examples which present the problems in the installation of Eddy Current Sensor and the solution for the problems,this paper analyzes the influence of the fixing space and the character of the conductor measured on the measurement. The article also provided the experiment data and analysis of the examples,which made the reference for the eddy-current sensor installation.

关键词(KeyWords): TSI;电涡流探头;轴位移;轴振
TSI; eddy current sensor; shaft displacement; shaft vibration