浙江电力

2009, v.28;No.v.28(04) 25-27

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

超临界直流锅炉破坏炉底水封运行尝试
Operation Attempt on Destroyed Water Seal in Suppercritical Once-through Boiler

张乐君
ZHANG Le-jun(Zhejiang Zheneng Lanxi power Generation Co.Ltd.

摘要(Abstract):

介绍超临界直流锅炉破坏水封不停炉运行的过程,通过对前后主要参数变化的分析,对破坏水封不停炉处理操作要点及注意事项进行探讨。
The paper introduces that suppercritical once-through boiler was still running while water seal was destroyed.Based on analyzing the mian parameters,the paper discusses the key points and attentions of operation while water seal was destroyed.

关键词(KeyWords): 超临界;直流锅炉;水封
supercritical;once through boiler;water seal

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 张乐君
ZHANG Le-jun(Zhejiang Zheneng Lanxi power Generation Co.Ltd.

DOI: 10.19585/j.zjdl.2009.04.008