凝结水节流调频负荷特性测试与评估Test and Assessment on Load Characteristic of Frequency Modulation by Condensate Throttling
张宝,童小忠,罗志浩,吴文健,章卫军
ZHANG Bao1,TONG Xiao-zhong1,LUO Zhi-hao1,WU Wen-jian1,ZHANG Wei-jun2(1.Z(P)EPC Electric Power Research Institute
摘要(Abstract):
作为一种新的调频形式,通过凝结水节流来快速调整机组负荷的技术日益受到重视。对凝结水节流调频技术进行理论分析,介绍了凝结水节流负荷特性的现场测试方法,通过测试实例证实了凝结水节流所产生的功率改变量与凝结水的流量变化成比例这一规律;在此基础上给出了凝结水节流调频潜力评估的方法。
As a new method for frequency modulation,fast adjustment of unit load by condensate throttling has gained more and more attention.The paper theoretically analyzes frequency modulation by condensate throttling and introduces filed test method for load characteristic of frequency modulation by condensate throttling.It is proved by test examples that power variation due to condensate throttling proportionates to condensate flow variation,on the basis of which method for assessing potential of frequency modulation by condensate modulation is proposed.
关键词(KeyWords):
汽轮机;凝结水节流;负荷特性;测试;分析
steam turbine;condensate throttling;load characteristics;test;analysis
基金项目(Foundation): 国家电网浙江省电力公司科技项目资助(ZDK026-20121201)
作者(Author):
张宝,童小忠,罗志浩,吴文健,章卫军
ZHANG Bao1,TONG Xiao-zhong1,LUO Zhi-hao1,WU Wen-jian1,ZHANG Wei-jun2(1.Z(P)EPC Electric Power Research Institute
DOI: 10.19585/j.zjdl.2013.02.013
参考文献(References):
- 姚峻,高磊,陈维和,等.900 MW超临界机组协调控制及AGC策略的研究与应用[J].中国电力,2005,38(8):62-65.
- 陈小强,项谨,魏路平,等.1 000 MW机组一次调频性能优化[J].中国电力,2010,43(4):63-66.
- 姚峻,祝建飞,金峰.1 000 MW机组节能型协调控制系统的设计与应用[J].中国电力,2010,43(6):79-84.
- 刘鑫平,田亮,曾德良,等.凝结水节流参与机组负荷调节过程建模与分析[J].华北电力大学学报,2009,36(2):80-83.
- 王国凯,张峰,展宗波,等.凝结水节流技术在电厂的应用探讨[J].内蒙古电力技术,2011,29(2):45-47.