浙江电力

2011, v.30;No.188(12) 50-52

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

600MW亚临界汽包炉炉水氢氧化钠调节处理试验研究
Research on Test of Adjustment and Treatment of Sodium Hydroxide in 600MW Subcritical Drum Boiler Water

葛雪静,徐锦影,宋敬霞
GE Xue-jing1,XU Jin-ying1,SONG Jing-xia2(1.Guohua Ninghai Power Plant

摘要(Abstract):

介绍了浙江国华宁海电厂4号机组锅炉炉水由磷酸盐处理改为氢氧化钠处理的试验和运行情况。结果表明,炉水采用氢氧化钠处理方式后,含盐量明显降低,炉水品质得到改善,从而使蒸汽钠含量明显降低,减少了过热器和汽轮机的积盐风险,对电厂的节能降耗具有重要意义。
This paper introduces the test and operation situation of replacing phosphate treatment with sodium hydroxide treatment for Unit 4 boiler water in Zhejiang Guohua Ninghai Power Plant.The result shows that the salinity of boiler water declined after sodium hydroxide treatment and the boiler water quality was improved so that it lowered the sodium content of vapor and reduced the salification risk in the superheater and steam turbine.It is of high significance for energy saving and consumption reduction in power plants.

关键词(KeyWords): 亚临界;汽包炉;磷酸盐处理;氢氧化钠处理;积盐
subcritical;drum boiler;phosphate treatment;sodium hydroxide treatment;salification

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 葛雪静,徐锦影,宋敬霞
GE Xue-jing1,XU Jin-ying1,SONG Jing-xia2(1.Guohua Ninghai Power Plant

DOI: 10.19585/j.zjdl.2011.12.014