多功能温度校验仪校准与使用中的问题与对策
Problem and Countermeasure of Multifunctional Temperature Calibration Device in Calibration and Application

冯素娟,孙长生
FENG Su-juan, SUN Chang-sheng(Zhejiang Electric Power Test and Research Institute

摘要(Abstract):

多功能温度校验仪越来越多地应用于现场校验,为现场检修维护人员提供了方便。但由于检定和使用中的一些不规范行为,增加了因测试操作不当而产生的附加误差,降低了测量精度。通过对多功能温度校验仪校准和使用过程中出现的问题的分析,提出了应用中注意的事项,供热工计量工作人员参考。
Multifunctional temperature calibration device is being widely used in field calibration, which provides great convenience to maintainer. However, due to the misoperation during using and calibration process, there comes problems with additional errors created, testing accuracy reduced. Through discussing problems appeared in application and calibration of multifunctional temperature calibration device, this paper gives some matters need attention, which shall give some reference to workers of this field.

关键词(KeyWords): 温度;校验仪;校准;使用;误差;精度
temperature; calibration device; calibration; application; error; precision