国产600MW超临界直流锅炉给水凝结水自动加氧处理技术的应用Application of Feed Water & Condensation Water Oxygenated Treatment Technology to the 600MW Supercritical Once-through Boiler
王奇伟,赵伟
WANG Qi-wei,ZHAO Wei(Zhejiang Datang Wushashan Power Generation Co.
摘要(Abstract):
以某发电厂1号机组为例,介绍国产超临界机组给水凝结水自动加氧处理技术的应用,阐述加氧装置自动改造的原因和必要性,以及加氧装置改造的过程、相关试验和改造后的运行效果评价。给水加氧成功改造后实现了加氧流量的自动控制,使给水凝结水溶解氧的含量可以维持在40~100μg/L,氧气消耗量比手动加氧运行方式下降50.0%,同时使给水自动加氧运行方式下的汽水品质更为优良、稳定,提高了加氧运行控制水平和机组运行的可靠性。
Taking a Unit 1 in a power plant for example,this paper particularly introduces the application of feed water oxygenated treatment on the 600 MW supercritical once-through boiler,explains the reason and necessity of automatic remolding of the oxygenated facilities,describes the remolding procedure and experiments and provides the assessment of the after-molding operation.The success of the remolding achieves the effective and automatic controlling of the oxygenated flow.Thus,the ratio of dissolved-oxygen in the feed water could keep at the level of 40~100 μg/L;the oxygen consumption decreases by 50.0%,compared with the manually-oxygenated operation.Meanwhile,with the technology of oxygenation,the quality of water could be higher and more stable,which consequently realizes better controlling of the oxygenating-operation and higher stability of the unit.
关键词(KeyWords):
超临界机组;给水;加氧;自动
supercritical unit;feed water;oxygenated;automatic
基金项目(Foundation):
作者(Author):
王奇伟,赵伟
WANG Qi-wei,ZHAO Wei(Zhejiang Datang Wushashan Power Generation Co.
DOI: 10.19585/j.zjdl.2012.10.021
参考文献(References):
- DL/T 805.1-2002火电厂汽水化学导则第1部分:直流锅炉给水加氧处理导则[S].北京:中国电力出版社,2002.
- 李永生,张好峰,郝晋堂,等.CWT给水处理新方法在调峰发电机组上的试验研究[J].东北电力学院学报,2003,23(4):38-43.
- G M W MANN,R GRANSEY.Waterside Corrosion As-sociated with Two Shift Boiler Operation on All Volatile Treatment Chemistry[J].Materials Performance,1980:32.
- 孙永,霍巨.直流锅炉给水联合处理在我国火电厂中的应用[J].热力发电,1998(4):42-45.
- 余晓琴,洪新华.国产亚临界直流炉给水加氧处理工艺的应用[J].华东电力,2000(12):7-9.
- 肖作善.热力设备水汽理化过程[M].北京:水利电力出版社,1987.
- 阿科利津.热能动力设备金属的腐蚀与保护[M].北京:水利电力出版社,1988.