浙江电力

2012, v.31;No.196(08) 69-71

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

超临界直流机组停(备)用保护工艺的选择与应用
Selection and Application of Shutdown(Reserve) Protection Techniques for Supercritical Once-through Unit

于汀,李志成,张铁,段国武
YU Ting,LI ZHi-cheng,ZHANG Tie,DUAN Guo-wu(Zhejiang Datang Wushashan Power Generation Co.

摘要(Abstract):

对采用给水加氧处理方式的600 MW超临界直流机组的停(备)用保护方法进行了对比优化,通过实施"氨水碱化烘干+负压抽真空"保护方法,利用现有设备,不需额外投资,操作简单、安全可靠,防锈蚀效果好、机组启动时间短、启动用水量少,取得了良好的效果。
The shutdown(reserve) protection techniques for the 600 MW supercritical once-through unit with oxygenated feedwater treatment are compared and optimized.The method of liquid ammonia alkalization drying + negative pressure vacuum pumping is adopted,in which the existing equipments are used without extra investment.It is also featured by easy operation,safety and reliability,good rust-proof effect,short startup time and less startup water consumption and achieves good effect.

关键词(KeyWords): 直流机组;停(备)用保护;氨水碱化烘干法;负压抽真空
once-through unit;shutdown(reserve) protection;liquid ammonia alkalization drying method;negative pressure vacuum pumping

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 于汀,李志成,张铁,段国武
YU Ting,LI ZHi-cheng,ZHANG Tie,DUAN Guo-wu(Zhejiang Datang Wushashan Power Generation Co.

DOI: 10.19585/j.zjdl.2012.08.020