浙江电力

2012, v.31;No.191(03) 31-34

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

发电机定子线棒堵塞治理与定冷水水质优化
Clogging Treatment for Generator Stator Bars and Quality Optimization for Stator Cooling Water

关玉芳,楼新明,冯礼奎
GUAN Yu-fang1,LOU Xin-ming1,FENG Li-kui2(1.Zheneng Lanxi Power Generation Co.

摘要(Abstract):

发电机定冷水系统在运行3年后出现定子线棒超温和温差大的问题,检查分析了出现这一现象的主要原因。对发电机定冷水系统采用了化学清洗方式清除积垢,清洗后线棒通流能力得到恢复,各线棒流量均一性得到改善。清洗后的定冷水系统采取碱化树脂对定冷水水质进行调整优化,提高了定冷水pH值,碱化处理方式对控制铜腐蚀、降低定冷水铜含量作用明显。
This paper performs the cause analysis of over-temperature and excessive temperature difference between the stator bars as the generator stator cooling water system has been in operation for three years.The chemical cleaning method is applied to remove the scale in the cooling water system.The flow capacity of the bars is recovered and the flow uniformity of all the bars is improved.The stator cooling water quality is optimized with alkalized resin after the cleaning to enhance pH of cooling water.Alkalization treatment is obviously effective to control copper corrosion and reduce the copper content in stator cooling water.

关键词(KeyWords): 发电机;定冷水;堵塞治理;水质优化
generator;stator cooling water;clogging treatment;water quality optimization

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 关玉芳,楼新明,冯礼奎
GUAN Yu-fang1,LOU Xin-ming1,FENG Li-kui2(1.Zheneng Lanxi Power Generation Co.

DOI: 10.19585/j.zjdl.2012.03.010

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享