锅炉尾部烟道漏风原因及防治Causes and Countermeasures against Air Leakage in the Tail Flue Gas Duct of the Boiler
王松峰,龚家猷,蔺海华
WANG Song-feng,GONG Jia-you,LIN Hai-hua(CSEC Guohua International Power Company Limited Beijing Cogeneration Branch
摘要(Abstract):
介绍了神华国华北京热电分公司锅炉尾部烟道漏风的情况,详细分析了导致尾部烟道漏风的原因,并提出相应的防治对策。
This paper introduces air leakage in the tail FG duct of the boiler of CSEC Guohua Beijing Cogeneration,and it analyzes causes for leakage and proposes relevant countermeasures.
关键词(KeyWords):
尾部烟道;空预器;漏风;露点温度
tail FG duct;air preheater;air leakage;dew point temperature
基金项目(Foundation):
作者(Author):
王松峰,龚家猷,蔺海华
WANG Song-feng,GONG Jia-you,LIN Hai-hua(CSEC Guohua International Power Company Limited Beijing Cogeneration Branch
DOI: 10.19585/j.zjdl.2013.02.015