摘要(Abstract):
建立基于PSCAD/EMTDC平台的并网光伏发电仿真模型,根据杭州能源与环境产业园并网光伏发电站实际运行中测得的运行数据,对并网光伏电站接入配电网的稳态电压分布、频率波动以及光伏电站的谐波和故障特性进行研究。全面评估光伏电站接入公共电网的安全性、可靠性,为光伏电站接入电网技术规定提供实际数据和理论支撑。
This paper presents the simulation model of grid-connected photovoltaic power system,studies the steady-state voltage distribution of the distribution feeder,the frequency fluctuation as well as its harmonic and fault characteristics according to the actual operation data of the grid-connected photovoltaic power station in Hangzhou Energy and Environment Industrial Park,comprehensively assesses the safety and reliability of the photovoltaic power stations connected with public power grid and provides the actual data and theoretical support for the technical requirements for photovoltaic power stations to connect with the grid.
关键词(KeyWords):
光伏发电;PSCAD/EMTDC;运行特性
photovoltaic power;PSCAD / EMTDC;operating characteristics
基金项目(Foundation):
作者(Author):
刘永胜,李题印,包拯民,黄河,姚海燕
LIU Yong-sheng,LI Ti-yin,BAO Zheng-ming,HUANG He,YAO Hai-yan(Yuhang Power Supply Bureau
DOI: 10.19585/j.zjdl.2011.03.002
参考文献(References):
- 刘伟,彭冬,卜广全,等.光伏发电接入智能配电网后的系统问题综述[J].电网技术,2009,33(19):1-6.
- 李珂,武家胜,杨泽伟,等.太阳能发电研究应用进展[J].浙江电力,2009,28(6):53-56.
- 杨卫东,薛峰,徐泰山,等.光伏并网发电系统对电网的影响及相关需求分析[J].水电自动化与大坝监测,2009,33(4):35-39,43.
- Baran M E,EI-Markaby I.Fault analysis on distributionfeeders with distributed generators[J].IEEE Transactionson Power Systems.2005,20(4):1757-1764.
- 谢昊,卢继平.重合闸在分布式发电条件下的应用分析[J].重庆大学学报,2007,30(2):30-33.
- 李晶,许洪华,赵海翔,等.并网光伏电站动态建模及仿真分析[J].电力系统自动化,2008,32(24):83-86.
- 刘飞,段善旭,殷进军,等.单级式光伏发电系统MPPT的实现与稳定性研究[J].电力电子技术,2008,42(3):28-30.
- LUO C,OOI B T.Frequency deviation of thermal powerplants due to wind farms.IEEE Transactions on EnergyConversion,2006,21(3):708-716.