超超临界对冲燃烧锅炉高温腐蚀研究Research on High-temperature Corrosion of Ultra-supercritical Opposed Firing Boiler
张基标
ZHANG Ji-biao(Zhejiang Zheneng Zhongmei Zhoushan Coal & Electricity Co.
摘要(Abstract):
针对某超超临界旋流燃烧锅炉燃烧器区域两侧墙水冷壁管向火侧外壁出现的高温腐蚀现象,通过对产生高温腐蚀的原因分析,提出了预防发生高温腐蚀的措施,有效防止了该现象的再次发生。
Through the cause analysis for the high-temperature corrosion of waterwall tube fireside external surface for the walls on both sides in the area of the swirl burner for the ultra-supercritical boiler,this paper presents the preventive measures that effectively avoid that phenomenon.
关键词(KeyWords):
超超临界锅炉;旋流燃烧;高温腐蚀;燃烧调整
ultra-supercritical boiler;swirl combustion;high-temperature corrosion;combustion adjustment
基金项目(Foundation):
作者(Author):
张基标
ZHANG Ji-biao(Zhejiang Zheneng Zhongmei Zhoushan Coal & Electricity Co.
DOI: 10.19585/j.zjdl.2011.04.002
参考文献(References):
- 岑可法,樊建人.锅炉和热交换器的积灰、结渣、磨损和腐蚀的防止原理与计算[M].北京:科学出版社,1994.[1]
- 裘立春,张建华.基于CO的燃煤锅炉燃烧优化[J].浙江电力,2005,24(3):10-12.[2]
- 牟春华,张义政,王春昌.某台墙式燃烧锅炉严重高温腐蚀和低负荷飞灰可燃物含量高的原因分析[J].热力发电,2008,37(7):39-42.[3]
- 丘纪华,刘永刚.对冲燃烧布置锅炉水冷壁高温腐蚀问题的研究[J].华中理工大学学报,1999,27(1):63-65.[4]
- 郭鲁阳,苏起.锅炉水冷壁高温腐蚀原因分析及预防对策[J].中国电力,2000,33(11):17-20.[5]
- 杨国旗.蒲城发电公司3号锅炉水冷壁减薄原因分析[J].西安电力高等专科学校学报,2008,3(1):61-64.[6]
- 超超临界锅炉
- 旋流燃烧
- 高温腐蚀
- 燃烧调整
ultra-supercritical boiler - swirl combustion
- high-temperature corrosion