摘要(Abstract):

根据浙江电网智能电能表运行情况,统计了智能电能表运行故障实例,针对运行故障发生数量较多的智能电能表烧毁、时钟电池欠压、时钟异常、继电器故障等进行了分析,并提出了相应的故障预防对策。
According to the operation of smart meters in Zhejiang province, this paper counts the examples operation faults of smart meters; it analyzes meters burning, undervoltage of clock batteries, clock abnormities, relay faults that frequently occur during the operation of smart meters. Moreover, it proposes countermeasures against faults accordingly.

关键词(KeyWords): 智能电能表;故障分析;对策