三支承结构的发电机-励磁机不稳定振动问题分析及治理Analysis and Treatment for Unstable Vibration of Three-bearing Generator Exciter System
应光耀,吴文健,童小忠
YING Guang-yao,WU Wen-jian,TONG Xiao-zhong(Zhejiang Electric Power Test and Research Institute
摘要(Abstract):
三支承结构发电机-励磁机机组一直存在着励磁机不稳定振动问题,其影响因素较多,治理困难。通过多台机组励磁机末端瓦振动的测试和治理,对振动故障进行研究,详细分析了影响振动的因素和振动机理,并提出相应的诊断策略和治理方法,有效解决了励磁机不稳定振动难题。
There has been the problem of unstable exciter vibration in three-bearing generator exciter system.It is difficult to solve it due to numerous influencing factors.Through the tests and treatment of the end bearing vibration of the exciters of a number of units,the research into the vibration fault is carried out,and the influencing factors and vibration mechanism are analyzed in detail.The diagnostic strategy and treatment methods are proposed and effectively solve the difficult problem.
关键词(KeyWords):
汽轮发电机组;励磁机;不稳定振动;分析;治理
steam turbine generator unit;exciter;unstable vibration;analysis;treatment
基金项目(Foundation):
作者(Author):
应光耀,吴文健,童小忠
YING Guang-yao,WU Wen-jian,TONG Xiao-zhong(Zhejiang Electric Power Test and Research Institute
DOI: 10.19585/j.zjdl.2011.05.009
参考文献(References):
- 沈佩华.引进型300 MW机组6,7号瓦振动爬升和不稳定问题的研究[J].热力发电,2004(1):39-41.
- 王延博,刘文,等.上海引进型300 MW机组发电机—励磁机振动特性综述[J].汽轮机技术,2004,46(6):454-457.
- 张学延,史建良,李德勇.国产600 MW汽轮发电机组振动问题分析及治理[J].热力发电,2009,38(9):1-4.
- 寇胜利,尹赐君.元宝山电厂600 MW发电机的振动[J].大电机技术,2003(6):20-25.
- 俞骏.国产超临界600 MW机组振动问题探讨[J].华东电力,2008,36(2)37-40.
- 何新有,倪定.600 MW励磁机轴承振动爬升故障诊断和处理[J].上海电力学院学报,2007,23(2):130-132.