660 MW机组汽动给水泵异常振动的分析与处理Analysis and Treatment of Abnormal Vibration of Steam Feed Pump for 660 MW Unit
马思聪,薄鼎彪,蔡文方
MA Sicong,BO Dingbiao,CAI Wenfang
摘要(Abstract):
某发电厂660 MW机组的汽动给水泵在运行中出现轴承振动超标的现象,通过进行振动测试和分析,判断振动超标的原因是转子质量不平衡、振动信号干扰、联轴器装配不良等,采取现场动平衡加重、更换振动测量原件、检修联轴器等措施后,成功消除了轴承的异常振动。
There was abnormal bearing vibration during steam feed pump operation of 660 MW units in a power plant. By vibration test and analysis, it was concluded that the causes were unbalanced rotor quality,vibration signal interference, poor coupling assembly. By taking the scene dynamic balance, replacing the original vibration measurement, coupling repair and other treatment measures, the abnormal vibration of the bearing was eliminated.
关键词(KeyWords):
汽动给水泵;轴承;振动;不平衡;信号干扰;联轴器
steam feed pump;bearing;vibration;unbalance;signal interference;coupling
基金项目(Foundation):
作者(Author):
马思聪,薄鼎彪,蔡文方
MA Sicong,BO Dingbiao,CAI Wenfang
DOI: 10.19585/j.zjdl.201809014
参考文献(References):
- [1]王文华,伍圣才.热电厂节能改造措施分析[J].广东科技,2015,24(12):81-84.
- [2]毛亚东,黄晓辰.汽动给水泵热经济性分析[J].能源研究与利用,2010(6):11-15.
- [3]马圣忠,杜洪波,李海峰.热电厂汽动给水泵节能技术研究与应用[J].山东煤炭科技,2014(3):192-193.
- [4]寇胜利.汽轮发电机组的振动及现场平衡[M].北京:中国电力出版社,2007.
- [5]陆颂元,吴峥峰.汽轮发电机组振动故障诊断及案例[M].北京:中国电力出版社,2016.
- [6]徐朔文.消除给水泵汽轮机振动监视干扰的案例分析[J].浙江电力,2013,32(4):42-44.
- [7]曹伟.热电厂TSI系统振动测量信号异常问题的分析[J].科技风,2015(6):150.
- [8]李自刚,李明,江俊.不对中联轴器-柔性转子系统非线性动力学行为[J].动力学与控制学报,2014(1):30-35.
- [9]李明,李自刚.联轴器不对中故障转子系统的动力学试验[J].振动、测试与诊断,2015,35(2):345-351.
- [10]宋光雄,宋君辉,梁会钊,等.大型旋转机械不对中故障研究及分析[J].汽轮机技术,2013,55(1):1-5.
- [11]钟达红,关南强,鲁周勋.湛江发电厂3号机组A给水泵汽轮机振动问题的分析处理[J].广东电力,2001,14(1):19-22.
- [12]张家伟,牟法海.300 MW机组汽动给水泵异常振动原因分析与处理[J].电站辅机,2015,36(2):44-46.
- [13]黄琪,于光辉,何东,等.接触刚度对汽轮机座缸式轴承振动特性的影响[J].汽轮机技术,2017,59(1):77-80.
- [14]宋光雄,宋君辉,梁会钊,等.大型电站机组油膜振荡故障研究分析[J].汽轮机技术,2013,55(3):161-167.