浙江电力

2013, v.32;No.202(02) 70-72

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

550 kV GIS开关更换技术研究
Research on the Replacement of Circuit Breaker in 550 kV GIS

吴浩,潘国跃,陈晓锦,蔡文发
WU Hao,PAN Guo-yue,CHEN Xiao-jing,CAI Wen-fa(Zhejiang Electric Transmission & Transformation Engineering Corporation

摘要(Abstract):

为了减少变电站技改工程中GIS气室的拆除数量,缩短停电时间,提出了一种更换GIS开关的技术方案,可在不拆除隔离开关、接地开关和快速接地开关的前提下更换开关。实践证明该方案是可行的,也能保证更换GIS开关的安全和质量。
In order to reduce the removal of GIS air chamber in technical transformation of substations and time of outage,the paper proposes a technical proposal for replacement of circuit breaker in GIS,which enables circuit breaker replacement without removing the disconnector,grounding switch and high speed grounding switch.It is practically proved that the proposal is workable and it can also ensure safety of GIS replacement and the quality.

关键词(KeyWords): GIS;断路器;工装;气室;更换
GIS;circuit breaker;tooling;air chamber;replacement