1000MW机组凝汽器钛管循环水泄漏侧的快速确认
Fast Diagnosis on Circulating Water Leakage Side of Condenser Titanium Tube of 1 000 MW Units

武云鹏
WU Yun-peng(Huaneng Yuhuan Power Plant

摘要(Abstract):

基于对目前1 000 MW汽轮发电机组在处理凝汽器钛管循环水严重泄漏时存在的问题分析,提出了一种简便高效的凝汽器循环水泄漏侧的快速确认方法,从而大大缩短凝结水水质恢复正常的时间,可避免机组因水质恶化而造成非计划停运和设备损坏。
On the basis of analyzing problems in handling serious circulating water leakage of condenser titanium tube of 1 000 MW turbo generating set,the paper proposes a fast,simple and effective diagnosis on circulating water leakage side of condenser.The time for quality recovery of condenser water is greatly shortened, which can keep the units away from unscheduled outage and damage due to deteriation of water quality.

关键词(KeyWords): 凝汽器;钛管;循环水;泄漏;1000MW机组
condenser;titanium tube;circulating water;leakage;1 000 MW units

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 武云鹏
WU Yun-peng(Huaneng Yuhuan Power Plant

DOI: 10.19585/j.zjdl.2012.12.014