摘要(Abstract):
由于循环硫化床锅炉无旁路控制系统,汽包水位不易控制,为此对汽包水位控制进行优化,使汽包水位能够完全满足锅炉各种工况运行的要求。
The drum water level cannot be easily controlled since the circulating fluidized bed boiler has no bypass system.Therefore the optimization of the drum water level control is performed to meet the requirements of boiler operation in all types of working conditions.