带电更换ZM塔悬垂串绝缘子专用卡具的设计及应用Design and Application of Dedicated Clamping Apparatus for Live Replacement of Suspension Insulator Strings for ZM Towers
周晓虎,汪建勤,吴宝贵,周秧
ZHOU Xiao-hu1,WANG Jian-qin2,WU Bao-gui1,ZHOU Yang1(1.Training Center of Zhejiang Electric Power Corporation
摘要(Abstract):
紧线丝杆法带电更换悬垂串绝缘子具有操作方便、效率高、适应性广等优点,但由于ZM型直线塔横担设计独特,无法采用该方法更换悬垂串绝缘子,限制了带电作业的顺利开展。为此提出了"卡具专用、丝杆通用"的设计思路,研制开发了适用于ZM塔形的通用提线丝杆,并已应用于数条500 kV线路,取得了良好效果。
The method of live replacement of suspension insulator strings with wire tightening lead screws is characteristic of convenient operation,high efficiency and extensive application.However,the method is unavailable due to the unique design of the ZM tower cross arms so that the live work is limited.This paper puts forward the design idea of "dedicated clamping apparatus,general lead screw" and develops the general line lifting lead screws suitable for the ZM towers.It has been applied to a number of 500 kV transmission lines and achieves desirable effect.
关键词(KeyWords):
带电作业;ZM塔;悬垂串绝缘子;更换
live work;ZM towers;suspension insulator strings;replacement
基金项目(Foundation):
作者(Author):
周晓虎,汪建勤,吴宝贵,周秧
ZHOU Xiao-hu1,WANG Jian-qin2,WU Bao-gui1,ZHOU Yang1(1.Training Center of Zhejiang Electric Power Corporation
DOI: 10.19585/j.zjdl.2012.06.020
参考文献(References):
- 国家电网公司组编.带电作业操作方法第1分册,输电线路[M].北京:中国电力出版社,2009.
- GB/T 15632-2008带电作业用提线工具通用技术条件[S].北京:中国标准出版社,2010.
- DL/T 463-2006带电作业用绝缘子卡具[S].北京:中国电力出版社,2006.
- 郝旭东,纪建民,智润仓.带电更换500 kV直线转角塔绝缘子串通用工具的研制[J].华北电力技术,2008(2):8-9.
- 刘鸿文.材料力学(第4版)[M].北京:高等教育出版社,2004.
- 电力安全工作规程(线路部分)[M].北京:中国电力出版社,2009.
- DL/T 966-2005送电线路带电作业技术导则[S].北京:中国电力出版社,2006.