浙江电力

2017, v.36;No.254(06) 55-58+79

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

300 MW机组锅炉尾部受热面的改造
Retrofit of Tail-Heating Surface of 300 MW Boilers

赵华,茅建波,孙迪辉
ZHAO Hua,MAO Jianbo,SUN Dihui

摘要(Abstract):

某发电厂300 MW亚临界机组锅炉低氮燃烧器改造后,存在主/再热蒸汽温度超温频繁、过热器减温水量大、SCR脱硝装置入口烟温高等问题。通过减少锅炉部分低温过热器、增加1组光管省煤器的尾部烟道受热面改造,彻底解决了上述问题,提高了机组运行的安全性和经济性,取得了良好的节能降耗效果。
After retrofit of low NOXburner of 300 MW subcritical boilers in a power plant, there are some problems such as overheated main steam and reheat steam, large quantity of desuperheating water and overheated inlet gas temperature of SCR denitration device. By reduction of low-temperature superheater and installation of a group of plain tube type economizer on the tail-heating surface, the aforementioned problems are solved. Therefore, operation safety and economy of the boilers are improved, and ideal effect of energy saving and consumption reduction is achieved.

关键词(KeyWords): 省煤器;受热面;SCR脱硝;减温水;改造
economizer;heating surface;SCR denitration;attemperation water;retrofit

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 赵华,茅建波,孙迪辉
ZHAO Hua,MAO Jianbo,SUN Dihui

DOI: 10.19585/j.zjdl.201706013

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享