介绍兰溪发电有限责任公司4号机600MW超临界机组由给水全挥发性处理工艺转换为加氧处理工艺的试验过程,及水汽指标的变化情况和原因,对比了3种给水处理工艺的水汽质量,对实施加氧后的现象进行了分析。
This paper introduces the test process of conversion from all-volatile treatment to oxygenation treatment of feedwater,the variations of steam-water indexes as well as the causes in feedwater treatment for No.4 600 MW supercritical unit in Lanxi Power Generation Co.,Ltd,and analyzes the phenomena after oxygenation by comparison of steam-water quality for three treatment technologies.