S109FA机组在日开夜停中的保温保压问题初探
Discussions of Temperature and Pressure Maintenance of S109FA Unit in Day-running and Night-down

俞立凡,王伟中
YU Li-fan,WANG Wei-zhong(Hangzhou Huadian Banshan Power Co. Ltd.

摘要(Abstract):

对日开夜停的燃气—蒸汽联合循环机组进行合理的保温保压,能加快余热锅炉升温升压速度、缩短机组加负荷的时间。介绍了S109FA机组在日开夜停中的保温保压目的及相关问题,对同类型机组具有较好的参考价值。
This article mainly discusses temperature and pressure maintenance problems of S109FA unit in day-running night-down shift. The conclusion will have good effects on increasing HRSG start-up speed and reducing the unit raise load time,and also offer a preferable reference to the same type unit.

关键词(KeyWords): S109FA;保温;保压
S109FA unit;temperature maintenance;pressure maintenance

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 俞立凡,王伟中
YU Li-fan,WANG Wei-zhong(Hangzhou Huadian Banshan Power Co. Ltd.

DOI: 10.19585/j.zjdl.2009.05.012