STAR-CCM+用于变压器温度场计算的可行性研究Feasibility Study of STAR-CCM+ for Transformer Temperature Field Calculation
沈海涛,马玉圣,金会会,吴卫东,王玉兴
SHEN Haitao,MA Yusheng,JIN Huihui,WU Weidong,WANG Yuxing
摘要(Abstract):
变压器温度场是影响变压器绝缘状态的重要因素之一,研究变压器温度分布对保证其正常工作、延长其使用寿命意义重大。首先,建立基于STAR-CCM+的油浸式变压器仿真模型,分析典型油浸式配电变压器的温度分布。然后,将仿真结果与红外测温实验结果进行对比,最大误差不超过7.5℃,验证了STAR-CCM+用于变压器温度场计算的可行性与可靠性。最后,提出利用STAR-CCM+研究绕组热点问题的简易方案,为变压器温度场分析和热点分布预测提供了一种新的计算方法。
Temperature field is one of the key influencing factors of the transformer insulation state. Therefore, it is of great significance to study the transformer temperature distribution to ensure the normal operation of the transformer and extend its service life. Firstly, an oil-immersed transformer simulation model based on STAR-CCM+ was established to analyze temperature distribution; secondly, the simulation result was compared with the experiment result of the infrared temperature measurement result, and the maximum error was within 7.5 ℃, demonstrating the feasibility and reliability of STAR-CCM+ for transformer temperature field calculation. Finally, a simple scheme of STAR-CCM+ is employed to study winding hot spots, providing a new calculation method for transformer temperature field analysis and hot spots prediction.
关键词(KeyWords):
变压器;温度场分布;热点;STAR-CCM+
transformers;temperature field distribution;hot spot;STAR-CCM+
基金项目(Foundation): 国家自然科学基金项目(61803332,51875510);; 国网湖北省电力有限公司科技支撑项目(SGTYHT/18-JS-206)
作者(Author):
沈海涛,马玉圣,金会会,吴卫东,王玉兴
SHEN Haitao,MA Yusheng,JIN Huihui,WU Weidong,WANG Yuxing
DOI: 10.19585/j.zjdl.202009007
参考文献(References):
- [1]张卫庆,王成亮,徐洪,等.变压器绕组热点温度检测研究现状综述[J].机电信息,2018(27):157-159.
- [2]刘弘景,张丹丹,李伟,等.大型油浸式变压器绕组温度场的有限元分析[J].高压电器,2019,55(12):83-89.
- [3]廖才波,阮江军,刘超,等.油浸式变压器三维电磁-流体-温度场耦合分析方法[J].电力自动化设备,2015,35(9):150-155.
- [4]陈伟根,苏小平,孙才新,等.基于有限体积法的油浸式变压器绕组温度分布计算[J].电力自动化设备,2011,31(6):23-27.
- [5]LI C H,SU B G,ZHOU G Y.FEM simulation of temperature field of dry-type transformerf C]//China International Conference on Electricity Distribution,Shenzhen,China:IEEE,2013:1-4.
- [6]黄娇.干式变压器温度场的研究[D].青岛:山东科技大学,2017.
- [7]姚鑫,张长胜,李英娜,等.基于ANSYS CFX的变压器绕组温度场监测研究[J].传感器与微系统,2018,37(4):77-79.
- [8]薛飞,陈炯,周健聪,等.基于ANSYS软件的油浸式变压器温度场有限元仿真计算[J].上海电力学院学报,2015,31(2):113-116.
- [9]段辞涵,阮江军,邓永清,等.变压器温度场计算边界辐射-对流复合换热等效方法研究[J/OL].电机与控制学报,2020:1-9.(2020-01-10)[2020-02-05].http://kns.cnki.net/kcms/detail/2 3.1408.TM.20200110.13 3 0.002.html.
- [10]时圣雨.磁屏蔽对电力变压器磁场与温度场的影响探究[J].中国设备工程,2018(17):152-153.
- [11]杨硕.S11-2000/10/0.4型油浸式变压器内温度场模拟研究[D].北京:华北电力大学,2015.
- [12]全妤,阮江军,龚若涵,等.基于流线和SVR的变压器热点温度反演方法[J].电工电能新技术,2018,37(11):23-31.
- [13]朱玉华,付思.基于流固耦合的干式变压器温度场数值分析[J].变压器,2019,56(1):53-57.
- [14]刘博.矿用干式变压器内部温度场的仿真研究[J].机械管理开发,2019(11):59-61.
- [15]李传峰.某新车型发动机舱热管理的研究与改进[D].上海:上海交通大学,2013.
- [16]叶冰清.汽车尾气温差发电装置热端与消声器结构集成设计研究[D].武汉:武汉理工大学,2013.
- [17]许晓文,孙后环,华广胜.基于STAR-CCM+汽车散热器的换热分析及结构优化[J].车辆与动力技术,2017(2):44-49.
- [18]NOBORU S.Thermal behavior analysis of lithium-ion bat teries for electric and hybrid vehicle[J].Journal of Power Sources,2005(141):307-315.
- [19]王亚峰.某纯电动卡车电池组热管理研究[D].南京:南京理工大学,2016.
- [20]李大建.油浸式变压器温度场分析与油流对内部温升影响因素研究[D].成都:西南交通大学,2013.
- [21]杜莉,王秀春.油浸式变压器内流场和温度场的数值模拟研究[J].变压器,2012,49(1):19-22.
- [22]章熙民,任泽需.传热学[M].北京:中国建筑工业出版社,2001.
- [23]霍亚俊,冯霆,宇文龙.500 kV变压器绝缘材料综合检测与应用[J].山西电力,2018(4):36-39.