摘要(Abstract):

干湿态转换是超超临界机组启动、停机过程中重要的技术环节。在总结国电北仑电厂、华能玉环电厂超超临界机组干湿态转换特点的基础上,详细介绍了超超临界机组运行状态转换过程中的主要技术难点,并给出了相应的分析和解决方法。
Conversion between dry and wet status is the most important technical section for ultra supercritical units in startup and shut down period.According to the main problems met in Yuhuan Power Plant and Beilun III project,the corresponding analysis and solve methods were presented.