浙江电力

2013, v.32;No.201(01) 56-58

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

600MW机组凝泵变频运行振动分析及治理
Cause Analysis and Control over Vibration of Condensate Pump of 600 MW Units in Variable-frequency Operation

陈伯权,刘明军,吴志强
CHEN Bo-quan,LIU Ming-jun,WU Zhi-qiang(Zheneng Beilun Power Generation Co.

摘要(Abstract):

某600 MW机组凝结水泵经变频改造后在变频工作区运行振动很大。通过对凝泵筒体进行理论建模计算分析,了解变频设备在变频运行范围内的特性,结合现场实际情况对凝泵先后进行了3次加固改造,有效解决了凝泵振动大的问题。
The condensate pump of 600 MW vibrates greatly in variable-frequency working area after frequency conversion.By modeling of condensate pump for calculation and analysis,characteristic of variable-frequency equipment in scope of variable-frequency operation are learned.In combination with field practices,the condensate pump is reinforced three times,which effectively solved the problem of the great vibration of condensate pump.

关键词(KeyWords): 凝结水泵;变频;振动治理
condensate pump;frequency conversion;vibration control

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 陈伯权,刘明军,吴志强
CHEN Bo-quan,LIU Ming-jun,WU Zhi-qiang(Zheneng Beilun Power Generation Co.

DOI: 10.19585/j.zjdl.2013.01.017

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享