火电厂锅炉减温器缺陷分析及预防Analysis and Prevention of Boiler Attemperator Defects in Thermal Power Plant
杨点中,胡洁梓,陈小林
YANG Dianzhong,HU Jiezi,CHEN Xiaolin
摘要(Abstract):
针对近年来浙江省发电厂锅炉减温器发生的部件失效和检查中发现的缺陷,对失效原因和相关危害影响进行分析,在此基础上对减温器的检验和监督管理提出应对措施。
Aiming at boiler attemperator parts failure and defects found by check in power plants of Zhejiang province in recent years, the paper analyzes the failure causes and relevant hazard or influence, on the basis of which it offers some relevant measures of attemperator inspection and supervision management accordingly.
关键词(KeyWords):
锅炉减温器;失效分析;检验;监督管理;措施
boiler attemperator;failure analysis;inspection;supervision & management;measure
基金项目(Foundation):
作者(Author):
杨点中,胡洁梓,陈小林
YANG Dianzhong,HU Jiezi,CHEN Xiaolin
DOI: 10.19585/j.zjdl.2014.02.013