从火电厂脱硫工艺水水质指标与脱硫运行的关联着手,采用取样分析的方法,对比了火电厂工艺水和各类废水水质,通过调研在用工艺水对脱硫运行的影响,结合废水回用的实例,探讨了废水回用作脱硫工艺水的可行性,提出了回用实施思路。
This paper introduces the relationship between wet flue gas desulfurization(FGD) processing water quality index and desulfurization operation in thermal power plants.Through the sampling analysis,the quality of the processing water and different types of waste water are compared.The feasibility of reusing treated waste water as the processing water is discussed and the implementation method of reusing is put forward by investigating the influence of processing water on desulfurization operation combined with the application cases.