浙江电力

2010, v.29;No.172(08) 37-40

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

塔式炉T23水冷壁泄漏分析及措施
Analysis and Countermeasures of T23 Water Wall Leakage in Tower Type Boiler

顾宏伟,高锦尧
GU Hong-wei, GAO Jin-yao (Zhejiang Guohua Zheneng Power Generation Co.

摘要(Abstract):

通过分析宁海电厂5、6号锅炉T23水冷壁泄漏情况,提出了在基建调试期间采取的各项应对措施,并在锅炉水冷壁刚性附件结构设计、制造及T23水冷壁安装工艺等方面提出建议,为同类型锅炉提供借鉴。
This paper analyzes of the T23 water wall leakage of No.5 and No.6 Boilers in Ninghai Power Plant, puts forward various countermeasures during capital construction and comissioning period and make suggestions on the aspects of the structure design and manufacturing of the rigid accessories of the boiler water wall, installation technology of T23 water wall etc. to offer a reference for the same type of boilers.

关键词(KeyWords): T23;泄漏;分析;措施
T23; leakage; analysis; measures

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 顾宏伟,高锦尧
GU Hong-wei, GAO Jin-yao (Zhejiang Guohua Zheneng Power Generation Co.

DOI: 10.19585/j.zjdl.2010.08.012