410t/h锅炉低NOX燃烧器改造及运行优化
Retrofit and Operation Optimization of Low NOX Burner for 410 t/h Boiler

胡琦,龚家猷,胡伟
HU Qi 1,GONG Jia-you2,HU Wei 2 (1.Shenhua Guohua Electric Power Research Institute

摘要(Abstract):

介绍了国华北京热电分公司410 t/h锅炉低NOX燃烧器改造情况及运行优化试验,对燃烧调整试验进行了细致的分析,对改造后的运行情况进行了总结,为运行中如何控制NOX的排放提出了可操作的指导建议。
This paper introduces the low NOX burner retrofit and operation optimization tests for the 410 t / h boiler of CSEC Guohua Beijing Cogeneration Branch Company,analyzes the combustion adjustment tests in detail and summarizes the operation situation after the retrofit.The practical suggestions on how to control NOX emission in operation are also provided.