1000MW超超临界锅炉尾部受热面吹损的原因分析及预防
Cause Analysis and Prevention of Blowing Loss of Tail Heating Surface of 1 000 MW Ultra Supercritical Boiler

陈建江,王国友
CHEN Jian-jiang,WANG Guo-you(Huaneng Yuhuan Power Plant

摘要(Abstract):

针对华能玉环发电厂1 000 MW超超临界锅炉尾部受热面蒸汽吹损严重的情况,分析造成受热面蒸汽吹损的原因,并采取针对性的措施,较好地解决了受热面蒸汽吹损问题。
Aiming at serious steam blowing loss of tail heating surface of 1 000 MW ultra supercritical boiler in Huaneng Yuhuan Power Plant,the paper analyzes the causes and takes pertinent measures to better handle the steam blowing loss of heating surface.

关键词(KeyWords): 锅炉;蒸汽吹灰;尾部受热面;吹损;原因;预防
boiler;steam sootblowing;tail heating surface;blowing loss;cause;prevention