基于同轴电容的谐波电压监测及影响因素分析Harmonic voltage monitoring based on coaxial capacitor and the analysis of influencing factors
何文林,詹江杨
HE Wenlin,ZHAN Jiangyang
摘要(Abstract):
谐波含量是电能质量的关键指标,高电压等级电网的谐波电压监测水平尚不能完全满足电力企业生产需求。通过建立基于同轴电容末屏接地电流的谐波电压测试系统,分析了不同频率下电容量对谐波电压含有率测试结果的影响程度,实测表明电容量变化对谐波电压含有率的影响不大于2%;分析了绝缘性能与谐波电压含有率误差的关联关系,当tanδ(f)小于0.2时,谐波电压含有率测试误差不超过2%;实测了不同绝缘状态下tanδ(f)的变化范围,分析表明绝缘状态对谐波电压含有率影响不明显。
Harmonic content is a key indicator of power quality, and the level of harmonic voltage monitoring in high-voltage power grids still cannot fully meet the production needs of electric power enterprises. By establishing a harmonic voltage testing system based on the end screen grounding current of coaxial capacitor, the influence of capacitance on the test results of harmonic voltage content at different frequencies is analyzed. The actual measurement shows that the influence of capacitance change on the harmonic voltage content is no more than 2%. The correlation between insulation performance and the error of harmonic voltage content is analyzed: when tanδ is less than 0.2, the test error of harmonic voltage content is no more than 2%; the range of variation of tanδ(f) under different insulation states is measured, and the analysis shows that the influence of insulation state on harmonic voltage content rate is not significant.
关键词(KeyWords):
同轴电容;电流互感器;谐波电压;监测
coaxial capacitor;current transformer;harmonic voltage;monitor
基金项目(Foundation):
作者(Author):
何文林,詹江杨
HE Wenlin,ZHAN Jiangyang
DOI: 10.19585/j.zjdl.202303013
参考文献(References):
- [1]徐钦,袁奔.分布式电源接入对配电网电压质量的影响研究[J].电工技术,2020(3):15-17.XU Qin,YUAN Ben.Research on influence of distributed power supply access on voltage quality of distribution network[J].Electric Engineering,2020(3):15-17.
- [2]薛俊茹,赵世昌,李晓伟,等.谐波在不同电压等级下传播机理的研究[J].青海电力,2016,35(3):38-41.XUE Junru,ZHAO Shichang,LI Xiaowei,et al.Research on the propagation mechanism of harmonic wave under different level voltages[J].Qinghai Electric Power,2016,35(3):38-41.
- [3]孔小丽.谐波对电器设备的影响分析[J].黑龙江科学,2020,11(24):110-111.KONG Xiaoli.Analysis of influence of harmonic wave on electrical equipment[J]. Heilongjiang Science,2020,11(24):110-111.
- [4]张建平,潘星.500 kV变压器异常噪声与振动的原因分析[J].浙江电力,2006,25(3):6-10.ZHANG Jianping,PAN Xing.Analysis for abnormal noise and mechanical vibration of 500 kV transformer[J].Zhejiang Electric Power,2006,25(3):6-10.
- [5]姜春阳,刘俭,王雪,等.电磁式电压互感器谐波误差测量方法研究[J].中国测试,2021,47(3):163-168.JIANG Chunyang,LIU Jian,WANG Xue,et al.Research on test method of harmonic measurement error of inductive voltage transformer[J].China Measurement&Test,2021,47(3):163-168.
- [6]谢伟伦,黄志威,刘小沛.杂散电容对CVT谐波测量影响的处理方法研究[J].电力电容器与无功补偿,2020,41(2):59-63.XIE Weilun,HUANG Zhiwei,LIU Xiaopei.Study on the processing method of influence of stray capacitance on CVT harmonic measurement[J].Power Capacitor&Reactive Power Compensation,2020,41(2):59-63.
- [7]陈一悰,刘坤雄,张小庆,等.基于电容电流的谐波电压在线监测系统研制[J].智慧电力,2021,49(6):67-74.CHEN Yicong,LIU Kunxiong,ZHANG Xiaoqing,et al.Development of voltage harmonics online measurement system based on capacitor current[J].Smart Power,2021,49(6):67-74.
- [8]国家技术监督局.电能质量公用电网谐波:GB/T14549—1993[S].北京:中国标准出版社,1994.
- [9]王玲,冯宇,杨柳,等.电容式电压互感器谐波测量方法研究[J].电力电容器与无功补偿,2021,42(1):95-100.WANG Ling,FENG Yu,YANG Liu,et al.Study on harmonic measurement method of capacitor voltage transformer[J].Power Capacitor&Reactive Power Compensation,2021,42(1):95-100.
- [10]王宇航,刘有为.光学电压互感器谐波测量影响因素及分析[J].自动化仪表,2021,42(6):14-18.WANG Yuhang,LIU Youwei. Influencing factors and analysis of harmonic measurement of optical voltage transformer[J].Process Automation Instrumentation,2021,42(6):14-18.
- [11]肖耀荣,高祖绵.互感器原理与设计基础[M].沈阳:辽宁科学技术出版社,2003.
- [12]王世阁,张军阳.互感器故障及典型案例分析[M].北京:中国电力出版社,2013.
- [13]何文林.电容型电流互感器主屏局部绝缘缺陷检测[J].华东电力,1994,22(7):10-12.HE Wenlin. Detection of local insulation defects in the main screen of capacitive current transformer[J]. East China Electric Power,1994,22(7):10-12.
- [14]詹江杨,何文林,杨智,等.油浸正立式电流互感器绝缘受潮缺陷的诊断分析[J].浙江电力,2018,37(3):17-21.ZHAN Jiangyang,HE Wenlin,YANG Zhi,et al.Diagnosis on insulation damp defects of oil-immersed vertical current transformer[J]. Zhejiang Electric Power,2018,37(3):17-21.
- [15]陈砚圃,杨蕾,张介秋.基于组合余弦窗加权的高精度电力谐波分析[J].高压电器,2021,57(8):127-135.CHEN Yanpu,YANG Lei,ZHANG Jieqiu. Analysis on high precision power harmonic based on combinatorial cosine window weighting method[J].High Voltage Apparatus,2021,57(8):127-135.
- [16]王鹤蓉,关焕新,郭祎珅,等.基于混合卷积窗三谱线插值的谐波分析方法[J].山东电力技术,2021,48(2):30-34.WANG Herong,GUAN Huanxin,GUO Yishen,et al.A triple-spectrum-line interpolation harmonic analysis method based on hybrid convolution window[J]. Shandong Electric Power,2021,48(2):30-34.
- [17]冷全超,张展,王维,等.改进的变步长自适应谐波检测算法[J].电测与仪表,2022,59(11):133-138.LENG Quanchao,ZHANG Zhan,WANG Wei,et al.Improved adaptive harmonic detection algorithm with variable step size[J].Electrical Measurement&Instrumentation,2022,59(11):133-138.
- [18]马明,杜婉琳,白雪儿,等.配电网中串联补偿电容方案的谐波谐振分析[J].电测与仪表,2022,59(4):159-163.MA Ming,DU Wanlin,BAI Xueer,et al.Harmonic resonance analysis of series compensation capacitor scheme in distribution system[J]. Electrical Measurement&Instrumentation,2022,59(4):159-163.
- [19]罗海荣,徐丽娟,张逸,等.基于监测数据相关性分析的谐波趋势预警方法[J].电测与仪表,2022,59(5):123-128.LUO Hairong,XU Lijuan,ZHANG Yi,et al. Harmonic trend warning method based on correlation analysis of monitoring data[J].Electrical Measurement&Instrumentation,2022,59(5):123-128.