浙江电力

2009, v.28;No.163(05) 29-31

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

300MW亚临界锅炉末级过热器爆管的分析及预防
Analysis and Prevention for Tube Failure of Final Superheater in 300 MW Subcritical Boiler

徐少峰,彭福仁
XU Shao-feng1,PENG Fu-ren2(1. Zheneng Wenzhou Power Co. Ltd.

摘要(Abstract):

对300MW亚临界锅炉启动初期发生的末级过热器爆管事件进行分析,排除长期超温过热和水塞过热的可能性后,得出氧化皮脱落堵塞过热是爆管的主要原因,并给出防范的建议。
This paper analyzes the tube failure that happened at row 41 of final superheater twice during the early startup process in 300 MW subcritical boiler. The reason of tube failure is that iron oxide skin blocked tube. Some suggestions are given to prevent the accident.

关键词(KeyWords): 亚临界锅炉;末级过热器;爆管;原因
subcritical boiler;final superheater;tube failure;reason

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 徐少峰,彭福仁
XU Shao-feng1,PENG Fu-ren2(1. Zheneng Wenzhou Power Co. Ltd.

DOI: 10.19585/j.zjdl.2009.05.008