浙江电力

2011, v.30;No.177(01) 36-39

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

减少125MW机组汽包连续排污系统能量损失的对策
Countermeasures for Energy Loss of Drum Continuous Blowdown System for 125 MW Units

居国腾
JU Guo-teng(Zheneng Qianqing Power Generation Co.

摘要(Abstract):

通过对浙能钱清发电厂(2×125 MW)机组汽包连续排污系统存在的能量损失情况进行分析,提出了应对措施,以期进一步提高机组的热经济性,减少机组热力系统对外界环境的工质排放和热污染。
For further improvement of the heat economy and reduction of the environmental emission and thermal pollution for the units,this paper analyzes the energy loss of the drum continuous blowdown system for the units(2 × 125 MW) in Zheneng Qianqing Power Plant and proposes the countermeasures.

关键词(KeyWords): 汽包;锅炉;连续排污系统;能量损失;对策
drum;boiler;continuous blowdown system;energy loss;countermeasures

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 居国腾
JU Guo-teng(Zheneng Qianqing Power Generation Co.

DOI: 10.19585/j.zjdl.2011.01.011