摘要(Abstract):
通过对镇海300MW联合循环余热锅炉热力系统、自动控制程序和实际运行数据的分析研究 ,找出该余热锅炉启动速度慢的根本原因 ,经过设备和控制程序的相应改造 ,实现了余热锅炉的安全快速启动 ,取得很好的经济效益