浙江电力

2013, v.32;No.211(11) 40-43

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

浙江省燃煤发电机组SCR烟气脱硝系统的运行状况评估
Operation Evaluation of SCR Flue Gas Denitration System of Coal-fired Power Generating Units in Zhejiang Province

曹志勇,陈聪,汤栋
CAO Zhi yong,CHEN Chong,TANG Dong

摘要(Abstract):

评估了浙江省内已经投产的17台SCR烟气脱硝机组的基本情况和投用率,分析了SCR烟气脱硝系统所产生的氨逃逸对空气预热器的影响,同时对几台投运时间较长的SCR烟气脱硝机组的空气预热器阻力进行对比分析,给出了提高燃煤机组SCR烟气脱硝系统投用率的建议,并提出了降低SCR烟气脱硝系统对燃煤机组不利影响的措施。
The background and operation rate of seventeen SCR flue gas denitration units of Zhejiang province are evaluated, and influence of ammonia slip from SCR system on air preheater is described. Advices of im- proving the operation rate of SCR flue gas denitration units and reducing the adverse effects of SCR system to coal-fired units are given.

关键词(KeyWords): 燃煤发电机组;烟气脱硝;评估;SCR
coal-fired power generating units;flue gas denitration;evaluation;SCR

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 曹志勇,陈聪,汤栋
CAO Zhi yong,CHEN Chong,TANG Dong

DOI: 10.19585/j.zjdl.2013.11.010