浙江电力

2013, v.32;No.210(10) 32-34+37

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

哈汽-东芝1000MW超超临界汽轮机中压转子冷却系统优化
Optimization of Cooling System for Intermediate Pressure Rotator of 1000 MW Supercritical Steam Turbine Designed by HTC and TSB

李大才,吴克锋,申建东,肖锋,李永俊
LI Da cai,WU Ke feng,SHEN Jian dong,XIAO Feng,LI Yong jun

摘要(Abstract):

针对哈汽-东芝1 000 MW超超临界汽轮机中压转子冷却系统运行中出现的问题,分析了中压转子冷却初参数变化对冷却效果的影响。通过对该中压转子冷却系统进行的优化改进,提高了机组可靠性和运行效率。
Aiming at problems in operation of cooling system for intermediate pressure rotator of 1 000 MW supercritical steam turbine designed by HTC and TSB, the paper analyzes impact of initial cooling parameter change of intermediate pressure rotator on cooling effect. By optimization and retrofit of cooling system of intermediate pressure rotator, reliability and operation efficiency of the units are enhanced.

关键词(KeyWords): 1000MW汽轮机;中压转子;冷却;优化
1 000 MW steam turbine;intermediate pressure rotator;cooling;optimization

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 李大才,吴克锋,申建东,肖锋,李永俊
LI Da cai,WU Ke feng,SHEN Jian dong,XIAO Feng,LI Yong jun

DOI: 10.19585/j.zjdl.2013.10.008